EUVIMEDEUVIMED entdecken
Crossref

Biothiols-activated near-infrared frequency up-conversion luminescence probe for early evaluation of drug-induced hepatotoxicity

Xiao Ma, Qingchun Lan, Shufen Pan, Yuting Han, Yi Liu, Yongquan Wu

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342768 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Xiao Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzho…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Chemical and Drug Induced Liver Injury. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangxi Province, Graduate Research and Innovation Projects of Jiangsu Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel biothiols-sensitive near-infrared (NIR) fluorescent probe RhDN based on a rhodamine skeleton was developed for early detection of drug-induced hepatotoxicity in living mice. RhDN can be used not only as a conventional large stokes shift fluorescent (FL) probe, but also as a kind of anti-Stokes frequency upconversion luminescence (FUCL) molecular probe, which represents a long wavelength excitation (808 nm) to short wavelength emission (760 nm), and response to Cys/Hcy/GSH with high sensitivity. Compared with traditional FL methods, the FUCL method exhibited a lower detection limit of Cys, Hcy, and GSH in 75.1 nM, 101.8 nM, and 84.9 nM, respectively. We exemplify RhDN for tracking endogenously biothiols distribution in living cells and further realize real-time in vivo bioimaging of biothiols activity in mice with dual-mode luminescence system. Moreover, RhDN has been successfully applied to visualize the detection of drug-induced hepatotoxicity in living mice. Overall, this report presents a unique approach to the development of large stokes shift NIR FUCL molecular probes for in vitro and in vivo biothiols biosensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesChemical and Drug Induced Liver InjuryAnimalsMiceHumansInfrared RaysOptical ImagingGlutathioneSulfhydryl CompoundsCysteineRhodaminesHomocysteineLuminescence

Stichwörter der Autor:innen

Biological mercaptanChemodosimeterFrequency up-conversion luminescenceIn vivo bioimagingNear infrared

Substanzen

Fluorescent DyesGlutathioneSulfhydryl CompoundsCysteineRhodaminesHomocysteine

Autor:innen und Institutionen

  • Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China.
  • School of Engineering, China Pharmaceutical University, Nanjing, 211198, PR China. Electronic address: yiliu@cpu.edu.cn.
  • Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China. Electronic address: wyq@gnnu.edu.cn.

Förderung

  • Natural Science Foundation of Jiangxi Province
  • Graduate Research and Innovation Projects of Jiangsu Province
  • National Natural Science Foundation of China
  • Double Thousand Plan of Jiangxi Province

Zitieren

APA

Ma, X., Lan, Q., Pan, S., Han, Y., Liu, Y., & Wu, Y. (2024). Biothiols-activated near-infrared frequency up-conversion luminescence probe for early evaluation of drug-induced hepatotoxicity. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342768

Vancouver

Ma X, Lan Q, Pan S, Han Y, Liu Y, Wu Y. Biothiols-activated near-infrared frequency up-conversion luminescence probe for early evaluation of drug-induced hepatotoxicity. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342768

BibTeX
@article{Ma2024,
  author = {Ma, Xiao and Lan, Qingchun and Pan, Shufen and Han, Yuting and Liu, Yi and Wu, Yongquan},
  title = {Biothiols-activated near-infrared frequency up-conversion luminescence probe for early evaluation of drug-induced hepatotoxicity},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342768}
}
Kostenlos starten →