Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening

Nadtinan Promphet, Chusak Thanawattano, Chatchai Buekban, Thidarut Laochai, Panlop Lormaneenopparat, Wiwittawin Sukmas, Pranee Rattanawaleedirojn, Pumidech Puthongkham, Pranut Potiyaraj, Worapong Leewattanakit, Nadnudda Rodthongkum

Analytica Chimica Acta · 2024-07 · 1312 · 342761

DOI: 10.1016/j.aca.2024.342761 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-07. Verfasst von Nadtinan Promphet und 10 weiteren Autor:innen. Beteiligte Einrichtung: Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Smartphone, Sweat, Biosensing Techniques. Die Arbeit wurde bisher 71-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Diabetes is a significant health threat, with its prevalence and burden increasing worldwide indicating its challenge for global healthcare management. To decrease the disease severity, the diabetic patients are recommended to regularly check their blood glucose levels. The conventional finger-pricking test possesses some drawbacks, including painfulness and infection risk. Nowadays, smartphone has become a part of our lives offering an important benefit in self-health monitoring. Thus, non-invasive wearable sweat glucose sensor connected with a smartphone readout is of interest for real-time glucose detection. RESULTS: Wearable sweat glucose sensing device is fabricated for self-monitoring of diabetes. This device is designed as a body strap consisting of a sensing strip and a portable potentiostat connected with a smartphone readout via Bluetooth. The sensing strip is modified by carbon nanotubes (CNTs)-cellulose nanofibers (CNFs), followed by electrodeposition of Prussian blue. To preserve the activity of glucose oxidase (GOx) immobilized on the modified sensing strip, chitosan is coated on the top layer of the electrode strip. Herein, machine learning is implemented to correlate between the electrochemical results and the nanomaterial content along with deposition cycle of prussian blue, which provide the highest current response signal. The optimized regression models provide an insight, establishing a robust framework for design of high-performance glucose sensor. SIGNIFICANCE: This wearable glucose sensing device connected with a smartphone readout offers a user-friendly platform for real-time sweat glucose monitoring. This device provides a linear range of 0.1-1.5 mM with a detection limit of 0.1 mM that is sufficient enough for distinguishing between normal and diabetes patient with a cut-off level of 0.3 mM. This platform might be an alternative tool for improving health management for diabetes patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesSmartphoneSweatBiosensing TechniquesMachine LearningDiabetes MellitusHumansGlucoseNanotubes, CarbonGlucose OxidaseElectrochemical Techniques

Stichwörter der Autor:innen

DiabetesMachine learningSmartphone readoutWearable glucose sensor

Substanzen

GlucoseNanotubes, CarbonGlucose Oxidase

Autor:innen und Institutionen

  • Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
  • National Electronics and Computer Technology Center (NECTEC), Pathumthani, 12120, Thailand.
  • Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Extreme Conditions Physics Research Laboratory and Center of Excellence i…
  • Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn Univ…
  • Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Department of Chemistry, Faculty of Science, Chulalongkorn University,…
  • Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Department of Materials Science, Faculty of Science, Chulalongkorn Univ…

Zitieren

APA

Promphet, N., Thanawattano, C., Buekban, C., Laochai, T., Lormaneenopparat, P., Sukmas, W., Rattanawaleedirojn, P., Puthongkham, P., Potiyaraj, P., Leewattanakit, W., & Rodthongkum, N. (2024). Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening. Analytica Chimica Acta, 1312, 342761. https://doi.org/10.1016/j.aca.2024.342761

Vancouver

Promphet N, Thanawattano C, Buekban C, Laochai T, Lormaneenopparat P, Sukmas W, et al. Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening. Analytica Chimica Acta. 2024;1312:342761. doi:10.1016/j.aca.2024.342761

BibTeX
@article{Promphet2024,
  author = {Promphet, Nadtinan and Thanawattano, Chusak and Buekban, Chatchai and Laochai, Thidarut and Lormaneenopparat, Panlop and Sukmas, Wiwittawin and Rattanawaleedirojn, Pranee and Puthongkham, Pumidech and Potiyaraj, Pranut and Leewattanakit, Worapong and Rodthongkum, Nadnudda},
  title = {Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening},
  journal = {Analytica Chimica Acta},
  year = {2024},
  volume = {1312},
  pages = {342761},
  doi = {10.1016/j.aca.2024.342761}
}
Kostenlos starten →