EUVIMEDEUVIMED entdecken
Crossref

Improving the detection accuracy of the dual SERS aptasensor system with uncontrollable SERS “hot spot” using machine learning tools

Junlin Chen, Hong Lin, Minqiang Guo, Limin Cao, Jianxin Sui, Kaiqiang Wang

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342631 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Junlin Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, Qingdao, Shandon…. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Aptamers, Nucleotide, Machine Learning, Silver. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Simultaneous detection of food contaminants is crucial in addressing the collective health hazards arising from the presence of multiple contaminants. However, traditional multi-competitive surface-enhanced Raman scattering (SERS) aptasensors face difficulties in achieving simultaneous accurate detection of multiple target substances due to the uncontrollable SERS "hot spots". In this study, using chloramphenicol (CAP) and estradiol (E2) as two target substances, we introduced a novel approach that combines machine learning methods with a dual SERS aptasensor, enabling simultaneous high-sensitivity and accurate detection of both target substances. RESULTS: The strategy effectively minimizes the interference from characteristic Raman peaks commonly encountered in traditional multi-competitive SERS aptasensors. For this sensing system, the Au@4-MBA@Ag nanoparticles modified with sulfhydryl (SH)-CAP aptamer and Au@DTNB@Ag NPs modified with sulfhydryl (SH)-E2 aptamer were used as signal probes. Additionally, Fe3O4@Au nanoflowers integrated with SH-CAP aptamer complementary DNA and SH-E2 aptamer complementary DNA were used as capture probes, respectively. When compared to linear regression random forest, and support vector regression (SVR) models, the proposed artificial neural network (ANN) model exhibited superior precision, demonstrating R2 values of 0.963, 0.976, 0.991, and 0.970 for the training set, test set, validation set, and entire dataset, respectively. Validation with ten spectral groups reported an average error of 244 μg L-1. SIGNIFICANCE: The essence of our study lies in its capacity to address a persistent challenge encountered by traditional multiple competitive SERS aptasensors - the interference generated by uncontrollable SERS "hot spots" that hinders simultaneous quantification. The accuracy of the predictive model for simultaneous detection of two target substances was significantly improved using machine learning tools. This innovative technique offers promising avenues for the accurate and high-sensitive simultaneous detection of multiple food and environmental contaminants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrum Analysis, RamanAptamers, NucleotideMachine LearningSilverGoldMetal NanoparticlesChloramphenicolEstradiolBiosensing TechniquesFood ContaminationLimit of Detection

Stichwörter der Autor:innen

BiosensorFood contaminantsNeural networkSimultaneous detectionSurface-enhanced Raman scattering (SERS)

Substanzen

Aptamers, NucleotideSilverGoldChloramphenicolEstradiol

Autor:innen und Institutionen

  • State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong, 266003, China.
  • State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong, 266003, China; College of Food Science and Engineering, Xinjiang In…
  • State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong, 266003, China. Electronic address: wkq@ouc.edu.cn.

Förderung

  • China Postdoctoral Science Foundation

Zitieren

APA

Chen, J., Lin, H., Guo, M., Cao, L., Sui, J., & Wang, K. (2024). Improving the detection accuracy of the dual SERS aptasensor system with uncontrollable SERS “hot spot” using machine learning tools. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342631

Vancouver

Chen J, Lin H, Guo M, Cao L, Sui J, Wang K. Improving the detection accuracy of the dual SERS aptasensor system with uncontrollable SERS “hot spot” using machine learning tools. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342631

BibTeX
@article{Chen2024,
  author = {Chen, Junlin and Lin, Hong and Guo, Minqiang and Cao, Limin and Sui, Jianxin and Wang, Kaiqiang},
  title = {Improving the detection accuracy of the dual SERS aptasensor system with uncontrollable SERS “hot spot” using machine learning tools},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342631}
}
Kostenlos starten →