Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342587 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Yizhou Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW, 2109, Australia. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Electrochemical Techniques, Nanostructures, Thrombin. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health and Medical Research Council, Macquarie University, Australian Research Council.
Abstract (Originalsprache)
Tetrahedral DNA nanostructure (TDN) is highly promising in developing electrochemical aptamer-based (E-AB) sensors for biomolecular detection, owing to its inherit programmability, spatial orientation and structural robustness. However, current interrogation strategies applied for TDN-based E-AB sensors, including enzyme-based amperometry, voltammetry, and electrochemical impedance spectroscopy, either require complicated probe design or suffer from limited applicability or selectivity. In this study, a TDN pendulum-empowered E-AB sensor interrogated by chronoamperometry for reagent-free and continuous monitoring of a blood clotting enzyme, thrombin, was developed. TDN pendulums with extended aptamer sequences at three vertices were immobilized on a gold electrode via a thiolated double-stranded DNA (dsDNA) at the fourth vertex, and their motion is modulated by the bonding of target thrombin to aptamers. We observed a significantly amplified signalling output on our sensor based on the TDN pendulum compared to E-AB sensors modified with linear pendulums. Moreover, our sensor achieved highly selective and rapidly responsive measurement of thrombin in both PBS and artificial urine, with a wide dynamic range from 1 pM to 10 nM. This study shows chronoamperometry-enabled continuous biomarker monitoring on a sub-second timescale with a drift-free baseline, demonstrating a novel approach to accurately detect molecular dynamics in real time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW, 2109, Australia.
- School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW, 2109, Australia; School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Austra…
- Division of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 630-0192, Ikoma, Japan.
Förderung
- National Health and Medical Research Council
- Macquarie University
- Australian Research Council
Zitieren
APA
Wang, Y., Duan, H., Yalikun, Y., Cheng, S., & Li, M. (2024). Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342587
Vancouver
Wang Y, Duan H, Yalikun Y, Cheng S, Li M. Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342587
BibTeX
@article{Wang2024,
author = {Wang, Yizhou and Duan, Haowei and Yalikun, Yaxiaer and Cheng, Shaokoon and Li, Ming},
title = {Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342587}
}
EUVIMED