EUVIMEDEUVIMED entdecken
Open Access

Large-volume RT-LAMP enables extraction-free amplification of HIV RNA from fingerstick plasma

Qin Wang, Shane D Gilligan-Steinberg, Wookyeom Kim, Enos C Kline, Ian T Hull, James J Lai, Barry R Lutz

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Qin Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, RNA, Viral. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, National Institutes of Health, National Institute of Allergy and Infectious Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Point-of-care (POC) nucleic acid amplification tests (NAAT) can significantly expand testing coverage, which is critical for infectious disease diagnostics and monitoring. The development of various isothermal amplification techniques greatly simplifies NAATs, but the cumbersome nucleic acid extraction step remains a bottleneck for the POC. Alternatively, extraction-free amplification, where crude samples are directly added into the assay, substantially simplifies the workflow. However, sample dilution is often needed in extraction-free amplification to reduce assay inhibition from sample matrices. Since NAATs are typically run at small volumes around 20 μL, the input sample quantity is therefore limited, resulting in an inevitable sensitivity loss. RESULTS: Here we explore the potential to perform isothermal amplification in larger reaction volumes to accommodate larger sample quantities, thereby improving sensitivity in extraction-free amplification. We demonstrated the approach by developing large-volume reverse transcription loop-mediated isothermal amplification (RT-LAMP) for HIV RNA detection from fingerstick plasma. We found that LAMP at reaction volumes up to 1 mL maintained the same performance. We then identified plasma dilution conditions needed to maintain the limit of detection in RT-LAMP. Subsequently, using inactivated HIV virus, we showed the successful detection of 24 HIV RNA copies in a 500 μL RT-LAMP reaction in the presence of 20 μL plasma (fingerstick volumes), translating to a viral load of 1200 copies per mL. To reduce the increased reagent cost with expanded reaction volumes, we further identified lower-cost reagents with maintained assay performance. Moreover, we showed that large-volume LAMP, compared to 20 μL reactions, could tolerate higher concentrations of various inhibitors in the sample, such as albumin and GuSCN. SIGNIFICANCE AND NOVELTY: NAATs are conventionally conducted at small reaction volumes. Here we demonstrated that LAMP can be run at large reaction volumes (over 100 μL) with maintained assay performance, allowing sample inhibition to be mitigated while accommodating larger sample quantities. The same strategy of expanding reaction volumes could be applied to other isothermal amplification methods and various POC applications, to streamline test workflows and/or improve assay sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesRNA, ViralHumansHIV InfectionsHIV-1Limit of DetectionMolecular Diagnostic Techniques

Stichwörter der Autor:innen

Extraction-free amplificationFingerstick bloodInhibitorIsothermal amplificationPoint-of-careReaction volume

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA.
  • Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA; Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei, 106335, Taiwan.
  • Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA. Electronic address: blutz@uw.edu.

Förderung

  • NIAID NIH HHS
  • National Institutes of Health
  • National Institute of Allergy and Infectious Diseases

Zitieren

APA

Wang, Q., Gilligan-Steinberg, S. D., Kim, W., Kline, E. C., Hull, I. T., Lai, J. J., & Lutz, B. R. (2024). Large-volume RT-LAMP enables extraction-free amplification of HIV RNA from fingerstick plasma. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342560

Vancouver

Wang Q, Gilligan-Steinberg SD, Kim W, Kline EC, Hull IT, Lai JJ, et al. Large-volume RT-LAMP enables extraction-free amplification of HIV RNA from fingerstick plasma. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342560