Calibration transfer via filter learning
Analytica Chimica Acta · 2024-04 · 1298 · 342404
DOI: 10.1016/j.aca.2024.342404 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-04. Verfasst von Zhonghao Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, PR China. Electronic address: xzh@wzu.edu.cn. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province.
Abstract (Originalsprache)
BACKGROUND: Calibration transfer is an essential activity in analytical chemistry in order to avoid a complete recalibration. Currently, the most popular calibration transfer methods, such as piecewise direct standardization and dynamic orthogonal projection, require a certain amount of standard or reference samples to guarantee their effectiveness. To achieve higher efficiency, it is desirable to perform the transfer with as few reference samples as possible. RESULTS: To this end, we propose a new calibration transfer method by using a calibration database from a master instrument (source domain) and only one spectrum with known properties from a slave instrument (target domain). We first generate a counterpart of this spectrum in the source domain by a multivariate Gaussian kernel. Then, we train a filter to make the response function of the slave instrument equivalent to that of the master instrument. To avoid the need for labels from the target domain, we also propose an unsupervised way to implement our method. Compared with several state-of-the-art methods, the results on one simulated dataset and two real-world datasets demonstrate the effectiveness of our method. SIGNIFICANCE: Traditionally, the demand for certain amounts of reference samples during calibration transfer is cumbersome. Our approach, which requires only one reference sample, makes the transfer process simple and fast. In addition, we provide an alternative for performing unsupervised calibration transfer. As such, the proposed method is a promising tool for calibration transfer.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, PR China. Electronic address: xzh@wzu.edu.cn.
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, PR China. Electronic address: chenxj@wzu.edu.cn.
- ITAP, Irstea, Montpellier SupAgro, University of Montpellier, Montpellier, France.
- College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, PR China.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Zhejiang Province
Zitieren
APA
Xie, Z., Chen, X., Roger, J. M., Ali, S., Huang, G., & Shi, W. (2024). Calibration transfer via filter learning. Analytica Chimica Acta, 1298, 342404. https://doi.org/10.1016/j.aca.2024.342404
Vancouver
Xie Z, Chen X, Roger JM, Ali S, Huang G, Shi W. Calibration transfer via filter learning. Analytica Chimica Acta. 2024;1298:342404. doi:10.1016/j.aca.2024.342404
BibTeX
@article{Xie2024,
author = {Xie, Zhonghao and Chen, Xiaojing and Roger, Jean-Michel and Ali, Shujat and Huang, Guangzao and Shi, Wen},
title = {Calibration transfer via filter learning},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1298},
pages = {342404},
doi = {10.1016/j.aca.2024.342404}
}
EUVIMED