Label-free and highly-sensitive detection of calcium ions using a silicon-on-sapphire light-addressable potentiometric sensor
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342282 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Chiyu Ma und 10 weiteren Autor:innen. Beteiligte Einrichtung: Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhej…. Hauptthemen laut MEDLINE: Aluminum Oxide, Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, Natural Science Foundation of Zhejiang Province, Zhejiang University.
Abstract (Originalsprache)
BACKGROUND: Ionic calcium (Ca2+) plays a crucial role in maintaining normal physiological and biochemical functions within the human body. Detecting the concentration of Ca2+ is of utmost significance for various purposes, including disease screening, cellular metabolism research, and evaluating drug effectiveness. However, current detection approaches such as fluorescence and colorimetry face limitations due to complex labeling techniques and the inability to track changes in Ca2+ concentration. In recent years, extensive research has been conducted in this field to explore label-free and efficient approaches. RESULTS: In this study, a novel light-addressed potentiometric sensor (LAPS) using silicon-on-sapphire technology, has been successfully developed for Ca2+ sensing. The Ca2+-sensitive LAPS achieved a wide-range detection of Ca2+, ranging from 10-2 M to 10-7 M, with an impressive detection limit of 100 nM. These advancements are attributed to the ultra-thin silicon layer, silicon dioxide layer, and solid-state silicon rubber sensitive membrane around 6 μm. Furthermore, the sensor demonstrated the ability to dynamically monitor fluctuations in Ca2+ concentration ranging from 10-9 M to 10-2 M within a solution. Its remarkable selectivity, specificity, and long-term stability have facilitated its successful application in the detection of Ca2+ in human serum and urine. SIGNIFICANCE AND NOVELTY: This work presents a Ca2+-sensitive sensor that combines a low detection limit and a wide detection range. The development represents the emergence of a label-free and rapid Ca2+ detection tool with immense prospects in home-based health monitoring, community disease screening, as well as cellular metabolism, and drug screening evaluations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
- Key Laboratory of Advanced Drug Delivery Systems of Zhejiang Province, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China. Electronic address: weixinwei@zju.edu.cn.
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China. Electronic address: cnpwang@…
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China; Binjiang Institute of Zhejia…
Förderung
- China Postdoctoral Science Foundation
- Natural Science Foundation of Zhejiang Province
- Zhejiang University
- State Key Laboratory of Chemical Engineering
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Ma, C., Qiu, Y., Liang, T., Jiang, N., Kong, L., Wu, J., Sun, X., Ren, G., Wei, X., Wang, P., & Wan, H. (2024). Label-free and highly-sensitive detection of calcium ions using a silicon-on-sapphire light-addressable potentiometric sensor. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342282
Vancouver
Ma C, Qiu Y, Liang T, Jiang N, Kong L, Wu J, et al. Label-free and highly-sensitive detection of calcium ions using a silicon-on-sapphire light-addressable potentiometric sensor. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342282
BibTeX
@article{Ma2024,
author = {Ma, Chiyu and Qiu, Yong and Liang, Tao and Jiang, Nan and Kong, Liubing and Wu, Jianguo and Sun, Xianyou and Ren, Guangqing and Wei, Xinwei and Wang, Ping and Wan, Hao},
title = {Label-free and highly-sensitive detection of calcium ions using a silicon-on-sapphire light-addressable potentiometric sensor},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342282}
}
EUVIMED