EUVIMEDEUVIMED entdecken
Crossref

Quantification of prohibited substances and endogenous corticosteroids in saliva using traditional, alternative microextraction-based, and novel 3D printed sample-preparation methods coupled with LC-MS

Krzysztof Goryński, Łukasz Sobczak

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Krzysztof Goryński und 1 weiteren Autor:innen. Beteiligte Einrichtung: Bydgoszcz University of Science and Technology, Faculty of Chemical Technology and Engineering, Seminaryjna 3, 85-326, Bydgoszcz, Poland. Electronic …. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Narodowe Centrum Badań i Rozwoju.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oral fluid has gained significant interest as an alternative matrix for drug testing due to its easy and non-invasive collection. Despite these advantages, achieving suitably low limits of detection remains a clear challenge in the use of oral fluids for drug screening. In this study, we demonstrate that the application of commercially available SPME fibers followed by liquid chromatography tandem mass spectrometry can enable the comprehensive detection and confirmation of drugs in oral fluid samples. To this end, we develop and test a sample-preparation protocol for a panel of 46 drugs covering the most popular drugs of abuse and doping agents available worldwide. Human saliva samples were collected using a Salivette® device (CE IVD certified) and sampled using SPME devices coated with a C18 extraction phase. The proposed protocol was validated with respect to its lower limits of quantification (LLOQ), linearity, matrix effects, precision, and extraction recovery. Linearity was confirmed for all compounds (R2 > 0.97), except for testosterone (R2 = 0.953) and metandrostenolon (R2 = 0.958). Furthermore, 4 compounds suffered from matrix effects, with less than 10 % deviation from acceptance criteria. After analytical validation, saliva samples from volunteers were analyzed to determine free concentrations of cortisol at different times after awaking. Finally, a 3D-printed prototype device was designed and successfully applied to extract small molecules, thus demonstrating a new modern low-cost approach for bioanalysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryHumansChromatography, LiquidSalivaHydrocortisonePrinting, Three-DimensionalSolid Phase Microextraction

Stichwörter der Autor:innen

3D printingDoping substancesDrugsPolyamide non-coated device for adsorption-based microextractionSalivaSolid-phase microextraction

Substanzen

Hydrocortisone

Autor:innen und Institutionen

  • Bydgoszcz University of Science and Technology, Faculty of Chemical Technology and Engineering, Seminaryjna 3, 85-326, Bydgoszcz, Poland. Electronic address: gorynski@pbs.edu.pl.
  • Nicolaus Copernicus University in Toruń, Faculty of Pharmacy, Jurasza 2, 85-089, Bydgoszcz, Poland.

Förderung

  • Narodowe Centrum Badań i Rozwoju

Zitieren

APA

Goryński, K., & Sobczak, Ł. (2024). Quantification of prohibited substances and endogenous corticosteroids in saliva using traditional, alternative microextraction-based, and novel 3D printed sample-preparation methods coupled with LC-MS. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342236

Vancouver

Goryński K, Sobczak Ł. Quantification of prohibited substances and endogenous corticosteroids in saliva using traditional, alternative microextraction-based, and novel 3D printed sample-preparation methods coupled with LC-MS. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342236

BibTeX
@article{Goryski2024,
  author = {Goryński, Krzysztof and Sobczak, Łukasz},
  title = {Quantification of prohibited substances and endogenous corticosteroids in saliva using traditional, alternative microextraction-based, and novel 3D printed sample-preparation methods coupled with LC-MS},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342236}
}
Kostenlos starten →