Wearable filamentary continuous sensor for interstitial glucose detection in diabetes management
Analytica Chimica Acta · 2024-02 · 1290 · 342169
DOI: 10.1016/j.aca.2023.342169 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-02. Verfasst von Changxi Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Beijing, 100871, PR China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Diabetes Mellitus. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Chinese Academy of Meteorological Sciences, National Key Research and Development Program of China, Peking University First Hospital.
Themen: Diabetes mellitus
Abstract (Originalsprache)
The development of novel diabetes monitoring sensors is important for the diabetes management of millions of diabetic patients. This work reports a flexible filamentary continuous glucose monitoring (CGM) sensor. A multilayer CGM sensor has been constructed on titanium filament with low cost and ease of use. The sensor, made of flexible material, offers better adaptability and comfort than traditional rigid filament CGM sensors, allowing continuous monitoring of subcutaneous blood glucose levels to provide patients with treatment strategies. The performance and reliability of the sensor were verified through rat experiments. The trend of the increase and decrease of the detected current was generally consistent with the actual blood glucose, and the detected values were located in regions A and B of the Clarke error grid. The results show that the sensor has the advantages of high sensitivity, high accuracy and fast response speed, which is suitable for monitoring the blood glucose level for a long time and has a broad application prospect in diabetes monitoring, exercise monitoring, health management and clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Beijing, 100871, PR China.
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatmen…
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Beijing, 100871, PR China. Electronic address: ycui@pku.edu.cn.
Förderung
- Chinese Academy of Meteorological Sciences
- National Key Research and Development Program of China
- Peking University First Hospital
- National Natural Science Foundation of China
Zitieren
APA
Zhang, C., Luo, X., Yang, L., & Cui, Y. (2024). Wearable filamentary continuous sensor for interstitial glucose detection in diabetes management. Analytica Chimica Acta, 1290, 342169. https://doi.org/10.1016/j.aca.2023.342169
Vancouver
Zhang C, Luo X, Yang L, Cui Y. Wearable filamentary continuous sensor for interstitial glucose detection in diabetes management. Analytica Chimica Acta. 2024;1290:342169. doi:10.1016/j.aca.2023.342169
BibTeX
@article{Zhang2024,
author = {Zhang, Changxi and Luo, Xiaojin and Yang, Li and Cui, Yue},
title = {Wearable filamentary continuous sensor for interstitial glucose detection in diabetes management},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1290},
pages = {342169},
doi = {10.1016/j.aca.2023.342169}
}
EUVIMED