A fluorescence-based immunochromatographic assay using quantum dot-encapsulated nanoparticles for the rapid and sensitive detection of fetuin-B
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2023.342143 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Jingyuan Hou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Cardiovascular Diseases, Meizhou Clinical Institute of Shantou University Medical College, Meizhou, Guangdong, 514031, China; GuangDong En…. Hauptthemen laut MEDLINE: Quantum Dots, Biosensing Techniques, Nanoparticles. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province, National Natural Science Foundation of China, Guangzhou Municipal Science and Technology Project.
Abstract (Originalsprache)
Coronary artery disease (CAD) is the leading cause of death worldwide. Earlier detection of CAD improves treatment outcomes and secondary prevention. The circulating fetuin-B protein is considered to be a promising biomarker for the early detection of CAD. However, a facile and reliable clinical test for fetuin-B is still lacking. Herein, we describe a reliable fluorescent biosensor for detecting fetuin-B in plasma that combines quantum dots-doped polystyrene nanoparticles with an immunochromatographic assay strip (QNPs-ICAS). The QNPs served as detection signals in the QNPs-ICAS sensor system, which was based on a double-antibody sandwich structure. Under optimum experimental conditions, the biosensor exhibited a broad linear range of 1-200 ng mL-1 and a low detection limit of 0.299 ng mL-1. Furthermore, the proposed immunosensor demonstrated high sensitivity, satisfactory selectivity, good reproducibility, and excellent recovery. Finally, the performance and applicability of our QNPs-based ICAS system were validated in clinical samples using a commercial ELISA kit with excellent correlations (r = 0.98451, n = 116). To conclude, the proposed sensor served as a rapid, sensitive, and accurate method for detecting fetuin-B in actual clinical samples, thereby demonstrating its potential for preliminary CAD screening and diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Cardiovascular Diseases, Meizhou Clinical Institute of Shantou University Medical College, Meizhou, Guangdong, 514031, China; GuangDong Engineering Technology Research Center for Molecular Diagnostics of Card…
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510180, China.
- Center for Cardiovascular Diseases, Meizhou Clinical Institute of Shantou University Medical College, Meizhou, Guangdong, 514031, China.
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China. Electronic address: zhongzhixiong@mzrmyy.com.
Förderung
- Basic and Applied Basic Research Foundation of Guangdong Province
- National Natural Science Foundation of China
- Guangzhou Municipal Science and Technology Project
Zitieren
APA
Hou, J., Cao, Y., Deng, Q., Zhang, Q., Deng, X., Chen, Z., & Zhong, Z. (2024). A fluorescence-based immunochromatographic assay using quantum dot-encapsulated nanoparticles for the rapid and sensitive detection of fetuin-B. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.342143
Vancouver
Hou J, Cao Y, Deng Q, Zhang Q, Deng X, Chen Z, et al. A fluorescence-based immunochromatographic assay using quantum dot-encapsulated nanoparticles for the rapid and sensitive detection of fetuin-B. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2023.342143
BibTeX
@article{Hou2024,
author = {Hou, Jingyuan and Cao, Yue and Deng, Qiaoting and Zhang, Qunji and Deng, Xunwei and Chen, Zhenhua and Zhong, Zhixiong},
title = {A fluorescence-based immunochromatographic assay using quantum dot-encapsulated nanoparticles for the rapid and sensitive detection of fetuin-B},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2023.342143}
}