An in-fiber sensor for simultaneous measurement of cholesterol concentration and temperature based on SPR and MMI
Analytica Chimica Acta · 2024-01 · 1287 · 342043
DOI: 10.1016/j.aca.2023.342043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-01. Verfasst von Wanlu Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Hebei Provincial Natural Science Foundation, State Key Laboratory of Synthetical Automation for Process Industries, National Natural Science Foundation of China.
Abstract (Originalsprache)
In this paper, we design an in-fiber two-parameter sensor with multimode fiber (MMF)-Au film coated hollow fiber (HCF)-MMF structure, which can simultaneously excite Surface Plasmon Resonance (SPR) effect and Multimode Interference (MMI) effect. A composite material of Au nanoparticles/β-cyclodextrin (AuNPs/β-CD) is deposited on the surface of the Au film coated HCF to realize highly-sensitive measurement of cholesterol concentration. Here, the AuNPs can not only enhance the measurement sensitivity of the SPR sensor, but also increase the numbers of combination sites of β-CD and cholesterol. Then, to solve the cross-sensitivity problem between temperature and cholesterol, the glycerin is selected as a temperature-sensitive material to fill into the inner channel of the HCF, making the MMI sensor sensitive to temperature, and finally realizing the simultaneous measurement of cholesterol concentration and temperature. The experimental results demonstrate that the wavelength shift of the SPR and the MMI are 12.7 nm and 7.9 nm, respectively, when the cholesterol concentration changes from 0 to 500 nM. The temperature sensitivity of the SPR and the MMI are -0.9 nm/°C and 2.64 nm/°C, respectively, in the temperature range of 30°C-46 °C. In addition, the sensor shows good recognition ability of cholesterol molecules in serum environment, with good stability, selectivity and repeatability, and has broad application prospects in the biomedical field.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China.
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China.
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China; Stat…
- Key Laboratory of Bioresource Research and Development of Liaoning Province, College of Life and Health Sciences, National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Northeastern Univ…
Förderung
- Hebei Provincial Natural Science Foundation
- State Key Laboratory of Synthetical Automation for Process Industries
- National Natural Science Foundation of China
Zitieren
APA
Zheng, W., Han, B., Zhang, Y. N., Liu, L., & Zhao, Y. (2024). An in-fiber sensor for simultaneous measurement of cholesterol concentration and temperature based on SPR and MMI. Analytica Chimica Acta, 1287, 342043. https://doi.org/10.1016/j.aca.2023.342043
Vancouver
Zheng W, Han B, Zhang YN, Liu L, Zhao Y. An in-fiber sensor for simultaneous measurement of cholesterol concentration and temperature based on SPR and MMI. Analytica Chimica Acta. 2024;1287:342043. doi:10.1016/j.aca.2023.342043
BibTeX
@article{Zheng2024,
author = {Zheng, Wanlu and Han, Bo and Zhang, Ya-Nan and Liu, Lijun and Zhao, Yong},
title = {An in-fiber sensor for simultaneous measurement of cholesterol concentration and temperature based on SPR and MMI},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1287},
pages = {342043},
doi = {10.1016/j.aca.2023.342043}
}
EUVIMED