Hybridization chain reaction-enhanced electrochemically mediated ATRP coupling high-efficient magnetic separation for electrochemical aptasensing of cardiac troponin I
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2023.342034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Xiaolun Peng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jiangha…. Hauptthemen laut MEDLINE: Cardiovascular Diseases, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jianghan University.
Abstract (Originalsprache)
The sensitive and accurate detection of cardiac troponin I (cTnI) as a gold biomarker for cardiovascular diseases at an early stage is crucial but has long been a challenge. In this study, we presented such an electrochemical (EC) aptasensor by combining hybridization chain reaction (HCR)-enhanced electrochemically mediated atom transfer radical polymerization (eATRP) amplification with high-efficient separation of magnetic beads (MBs). Aptamer-modified MBs empowered effective recognition and separation of cTnI from complex samples with high specificity. The specific binding of cTnI and aptamer could release triggered DNA (T-DNA) into solution to drive an HCR process, which produced plentiful active sites for eATRP initiators labeling followed by initiating eATRP process. With the development of eATRP, a great many of electroactive polymer probes were continually in situ formed to generate amplified current output for signal enhancement. Compared to no amplification, HCR-enhanced eATRP promoted the signals by ∼10-fold, greatly improving detection sensitivity for low-abundant cTnI analysis. Integrating MBs as capture carriers with HCR-enhanced eATRP as amplification strategy, this EC aptasensor achieved a low detection limit of 10.9 fg/mL for cTnI detection. Furthermore, the reliable detectability and anti-interference were confirmed in serum samples, indicating its promising application toward early diagnosis of cardiovascular diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, 430056, Wuhan, China. Electronic address: pengxl0212@163…
- Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, 430056, Wuhan, China.
- Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry…
Förderung
- National Natural Science Foundation of China
- Jianghan University
Zitieren
APA
Peng, X., He, R., Xu, J., Cao, C., Wen, W., Zhang, X., & Wang, S. (2024). Hybridization chain reaction-enhanced electrochemically mediated ATRP coupling high-efficient magnetic separation for electrochemical aptasensing of cardiac troponin I. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.342034
Vancouver
Peng X, He R, Xu J, Cao C, Wen W, Zhang X, et al. Hybridization chain reaction-enhanced electrochemically mediated ATRP coupling high-efficient magnetic separation for electrochemical aptasensing of cardiac troponin I. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2023.342034
BibTeX
@article{Peng2024,
author = {Peng, Xiaolun and He, Rongxiang and Xu, Junhui and Cao, Chunhua and Wen, Wei and Zhang, Xiuhua and Wang, Shengfu},
title = {Hybridization chain reaction-enhanced electrochemically mediated ATRP coupling high-efficient magnetic separation for electrochemical aptasensing of cardiac troponin I},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2023.342034}
}
EUVIMED