EUVIMEDEUVIMED entdecken
Crossref

3D-printed colorimetric copper ion detection kit and portable fluorescent sensing device using smartphone based on ratiometric fluorescent probes

Mengyuan Liu, Hanchuang Zhu, Yikun Fang, Caiyun Liu, Kun Wang, Xiaohui Zhang, Xinke Li, Lixue Ma, Miaohui Yu, Wenlong Sheng, Baocun Zhu

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2023.341980 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Mengyuan Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Water Conservancy and Environment, University of Jinan, Jinan, 250022, China. Hauptthemen laut MEDLINE: Fluorescent Dyes, Copper. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shandong Academy of Sciences, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Copper ion (Cu2+) is not only a transition metal ion but also a significant environmental pollutant. The imbalance of Cu2+ content will threaten the safety of the environment and even life. The portable detection devices based on ratiometric fluorescent probes have garnered increasing attention and acclaim because of their reliable analysis parameters. Therefore, two Cu2+ ratiometric fluorescent probes (RH-1 and RH-2) were developed, which exhibit pronounced fluorescence changes, high sensitivity, excellent selectivity, and large Stokes shift. Both probes are capable of detecting Cu2+ in water and milk samples. It is worth noting that a 3D-printed fluorescence sensing device was constructed using RH-1, and a new 3D-printed copper ion detection kit was developed based on RH-2, enabling on-the-spot estimation of Cu2+ concentration. These devices significantly facilitate Cu2+ detection in daily life. RH-2 has been successfully employed for imaging Cu2+ in living cells and zebrafish. In conclusion, this work provides, for the first time, the 3D-printed ideal tools for detecting Cu2+. It also provides valuable insights for the establishment of on-site portable detection methods for other important substances.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesCopperAnimalsSmartphoneColorimetryZebrafishPrinting, Three-DimensionalSpectrometry, Fluorescence

Stichwörter der Autor:innen

3D-printed deviceBioimagingCopper ionsRatiometric fluorescent probe

Substanzen

Fluorescent DyesCopper

Autor:innen und Institutionen

  • School of Water Conservancy and Environment, University of Jinan, Jinan, 250022, China.
  • School of Water Conservancy and Environment, University of Jinan, Jinan, 250022, China. Electronic address: liucaiyun1982072@163.com.
  • Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China.

Förderung

  • National Natural Science Foundation of China
  • Shandong Academy of Sciences
  • Natural Science Foundation of Shandong Province
  • Project of Shandong Province Higher Educational Science and Technology Program

Zitieren

APA

Liu, M., Zhu, H., Fang, Y., Liu, C., Wang, K., Zhang, X., Li, X., Ma, L., Yu, M., Sheng, W., & Zhu, B. (2024). 3D-printed colorimetric copper ion detection kit and portable fluorescent sensing device using smartphone based on ratiometric fluorescent probes. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.341980

Vancouver

Liu M, Zhu H, Fang Y, Liu C, Wang K, Zhang X, et al. 3D-printed colorimetric copper ion detection kit and portable fluorescent sensing device using smartphone based on ratiometric fluorescent probes. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2023.341980

BibTeX
@article{Liu2024,
  author = {Liu, Mengyuan and Zhu, Hanchuang and Fang, Yikun and Liu, Caiyun and Wang, Kun and Zhang, Xiaohui and Li, Xinke and Ma, Lixue and Yu, Miaohui and Sheng, Wenlong and Zhu, Baocun},
  title = {3D-printed colorimetric copper ion detection kit and portable fluorescent sensing device using smartphone based on ratiometric fluorescent probes},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2023.341980}
}
Kostenlos starten →