Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-09. Verfasst von Yuting Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, Ch…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Electrochemical aptasensor has been widely studied, while its practical application is limited by the unavoidable variations of aptamer loading densities and low signal amplification efficiency. To overcome these restrictions, an immobilization-free and label-free electrochemical homogeneous aptasensor was constructed for carcinoembryonic antigen (CEA) assay by combining RecJf exonuclease-mediated target cycling strategy and rolling circle amplification technology. In this system, the pre-immobilization of aptamers or other relevant signal elements on the electrode substrate is no longer necessary, thus the electrochemical homogeneous aptasensor shows good versatility on different transducers. Moreover, the whole recognition and signal amplification process are activated instantaneously by a non-professional operation of the solution mixture. This strategy can not only increase the stability (95.1% after 30 days of storage) and reproducibility (2.12% among five independent electrodes), but also further improve the sensitivity (detection limit of fg mL-1 level) due to the free target recognition and dual signal amplification in the homogeneous solution phase. The proposed immobilization-free electrochemical homogeneous aptasensors on different electrode substrates both achieve satisfactory results in actual sample tests, which has the potential for commercial applications and the establishment of other target platforms in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China.
- The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology, Jiangnan University, Wuxi, 214122, China. Electronic address: zhounandi@jiangnan.edu.cn.
Förderung
- China Postdoctoral Science Foundation
Zitieren
APA
Zhang, Y., Li, H., Guo, Z., Wang, X., & Zhou, N. (2023). Immobilization-free electrochemical homogeneous aptasensor for highly sensitive detection of carcinoembryonic antigen by dual amplification strategy. Analytica Chimica Acta, 1274, 341586. https://doi.org/10.1016/j.aca.2023.341586
Vancouver
Zhang Y, Li H, Guo Z, Wang X, Zhou N. Immobilization-free electrochemical homogeneous aptasensor for highly sensitive detection of carcinoembryonic antigen by dual amplification strategy. Analytica Chimica Acta. 2023;1274:341586. doi:10.1016/j.aca.2023.341586
BibTeX
@article{Zhang2023,
author = {Zhang, Yuting and Li, Hui and Guo, Zongkang and Wang, Xiaoli and Zhou, Nandi},
title = {Immobilization-free electrochemical homogeneous aptasensor for highly sensitive detection of carcinoembryonic antigen by dual amplification strategy},
journal = {Analytica Chimica Acta},
year = {2023},
volume = {1274},
pages = {341586},
doi = {10.1016/j.aca.2023.341586}
}
EUVIMED