Mobile phase and column chemistry selection for high sensitivity non-targeted LC/ESI/HRMS screening of water

Amina Souihi, Miklos Peter Mohai, Jonathan W Martin, Anneli Kruve

Analytica Chimica Acta · 2023-09 · 1274 · 341573

DOI: 10.1016/j.aca.2023.341573 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-09. Verfasst von Amina Souihi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental and Materials Chemistry, Stockholm University, Svante Arrhenius väg 16, 106 91, Stockholm, Sweden. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Formas.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Systematic selection of mobile phase and column chemistry type can be critical for achieving optimal chromatographic separation, high sensitivity, and low detection limits in liquid chromatography electrospray high resolution mass spectrometry (LC/MS). However, the selection process is challenging for non-targeted screening where the compounds of interest are not preselected nor available for method optimization. To provide general guidance, twenty different mobile phase compositions and four columns were compared for the analysis of 78 compounds with a wide range of physicochemical properties (logP range from -1.46 to 5.48), and analyte sensitivity was compared between methods. The pH, additive type, column, and organic modifier had significant effects on the analyte response factors, and acidic mobile phases (e.g. 0.1% formic acid) yielded highest sensitivity. In some cases, the effect was attributable to the difference in organic modifier content at the time of elution, depending on the mobile phase and column chemistry. Based on these findings, 0.1% formic acid, 0.1% ammonia and 5.0 mM ammonium fluoride were further evaluated for their performance in non-targeted LC/ESI/HRMS analysis of wastewater treatment plan influent and effluent, using a data dependent MS2 acquisition and two different data processing workflows (MS-DIAL, patRoon 2.1) to compare number of detected features and sensitivity. Both data-processing workflows indicated that 0.1% formic acid yielded the highest number of features in full scan spectrum (MS1), as well as the highest number of features that triggered fragmentation spectra (MS2) when dynamic exclusion was used.

Schlagwörter

Stichwörter der Autor:innen

Data dependent acquisitionIdentification of unknownsIonization efficiencyLimit of detectionMethod optimization

Autor:innen und Institutionen

  • Department of Environmental and Materials Chemistry, Stockholm University, Svante Arrhenius väg 16, 106 91, Stockholm, Sweden.
  • Department of Environmental Science, Stockholm University, Svante Arrhenius väg 8, 106 91, Stockholm, Sweden; Science for Life Laboratory, Department of Environmental Science, Stockholm University, Svante Arrhenius väg…
  • Department of Environmental and Materials Chemistry, Stockholm University, Svante Arrhenius väg 16, 106 91, Stockholm, Sweden; Department of Environmental Science, Stockholm University, Svante Arrhenius väg 8, 106 91, S…

Förderung

  • Formas

Zitieren

APA

Souihi, A., Mohai, M. P., Martin, J. W., & Kruve, A. (2023). Mobile phase and column chemistry selection for high sensitivity non-targeted LC/ESI/HRMS screening of water. Analytica Chimica Acta, 1274, 341573. https://doi.org/10.1016/j.aca.2023.341573

Vancouver

Souihi A, Mohai MP, Martin JW, Kruve A. Mobile phase and column chemistry selection for high sensitivity non-targeted LC/ESI/HRMS screening of water. Analytica Chimica Acta. 2023;1274:341573. doi:10.1016/j.aca.2023.341573

BibTeX
@article{Souihi2023,
  author = {Souihi, Amina and Mohai, Miklos Peter and Martin, Jonathan W and Kruve, Anneli},
  title = {Mobile phase and column chemistry selection for high sensitivity non-targeted LC/ESI/HRMS screening of water},
  journal = {Analytica Chimica Acta},
  year = {2023},
  volume = {1274},
  pages = {341573},
  doi = {10.1016/j.aca.2023.341573}
}
Kostenlos starten →