EUVIMEDEUVIMED entdecken
Crossref

An integrated automatic lab-in-syringe sol-gel coated foam microextraction platform as a front-end to high performance liquid chromatography for the migration studies of bisphenol A

Natalia Manousi, Ioannis Priovolos, Abuzar Kabir, Kenneth G Furton, Victoria F Samanidou, Aristidis Anthemidis

Analytica Chimica Acta · 2023-08 · 1268 · 341400

DOI: 10.1016/j.aca.2023.341400 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-08. Verfasst von Natalia Manousi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece; Laboratory of Pharmac…. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The proof-of-concept of an integrated automatic foam microextraction lab-in-syringe (FME-LIS) platform coupled to high performance liquid chromatography is presented. Three different sol-gel coated foams were synthesized, characterized, and conveniently packed inside the glass barrel of the LIS syringe pump, as an alternative approach for sample preparation, preconcentration and separation. The proposed system efficiently combines the inherent benefits of lab-in-syringe technique, the good features of sol-gel sorbents, the versatile nature of foams/sponges, as well as the advantages of automatic systems. Bisphenol A (BPA) was used as model analyte, due to the increasing concern for the migration of this compound from household containers. The main parameters that affect the extraction performance of the system were optimized and the proposed method was validated. The limit of detection for BPA were 0.5 and 2.9 μg L-1, for a sample volume of 50 mL and 10 mL, respectively. The intra-day precision was

Schlagwörter

Stichwörter der Autor:innen

AutomationBisphenol AFoamHPLCLab-in-syringeMicroextractionSol-gel technologySponge

Autor:innen und Institutionen

  • Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece; Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessalo…
  • Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece.
  • International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, 33131, USA.
  • Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece. Electronic address: anthemid@chem.auth.gr.

Zitieren

APA

Manousi, N., Priovolos, I., Kabir, A., Furton, K. G., Samanidou, V. F., & Anthemidis, A. (2023). An integrated automatic lab-in-syringe sol-gel coated foam microextraction platform as a front-end to high performance liquid chromatography for the migration studies of bisphenol A. Analytica Chimica Acta, 1268, 341400. https://doi.org/10.1016/j.aca.2023.341400

Vancouver

Manousi N, Priovolos I, Kabir A, Furton KG, Samanidou VF, Anthemidis A. An integrated automatic lab-in-syringe sol-gel coated foam microextraction platform as a front-end to high performance liquid chromatography for the migration studies of bisphenol A. Analytica Chimica Acta. 2023;1268:341400. doi:10.1016/j.aca.2023.341400

BibTeX
@article{Manousi2023,
  author = {Manousi, Natalia and Priovolos, Ioannis and Kabir, Abuzar and Furton, Kenneth G and Samanidou, Victoria F and Anthemidis, Aristidis},
  title = {An integrated automatic lab-in-syringe sol-gel coated foam microextraction platform as a front-end to high performance liquid chromatography for the migration studies of bisphenol A},
  journal = {Analytica Chimica Acta},
  year = {2023},
  volume = {1268},
  pages = {341400},
  doi = {10.1016/j.aca.2023.341400}
}
Kostenlos starten →