EUVIMEDEUVIMED entdecken
Crossref

A split-type photoelectrochemical immunosensing platform based on atom-efficient cation exchange for physiological monitoring

Xue Wang, Dongquan Leng, Faying Li, Lei Liu, Xiang Ren, Jin Yong Lee, Huangxian Ju, Qin Wei

Analytica Chimica Acta · 2023

DOI: 10.1016/j.aca.2023.341340 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Xue Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasensitive and accurate physiological monitoring is of great significance for disease diagnosis and treatment. In this project, an efficient photoelectrochemical (PEC) split-type sensor on the basis of controlled release strategy was established with great success. Heterojunction formation between g-C3N4 and Zn-doped CdS improved the visible light absorption efficiency, reduced carrier complexation, improved the PEC signal, and increased the stability of the PEC platform. Compared to the traditional model of immunosensors, the process of antigen-antibody specific binding was done in a 96 microplate, and the sensor separated the immune reaction from the photoelectrochemical conversion process, eliminating mutual interference. Cu2O nanocubes were used to label the second antibody (Ab2), and acid etching using HNO3 released a large amount of divalent copper ions, which exchanged cations with Cd2+ in the substrate material, causing a sharp drop in photocurrent and improving the sensitivity of the sensor. Under the optimized experimental conditions, the PEC sensor based on the controlled release strategy for CYFRA21-1 target detection had a wide concentration linear range of 5 × 10-5 to 100 ng/mL with a low detection limit of 0.0167 pg/mL (S/N = 3). This intelligent response variation pattern could also offer the possibility of additional clinical applications for other target detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesDelayed-Action PreparationsImmunoassayCationsElectrochemical TechniquesLimit of DetectionAntigens, NeoplasmKeratin-19

Stichwörter der Autor:innen

CYFRA21-1Controlled releaseCu(2)OImmunosensorPhotoelectrochemical

Substanzen

Delayed-Action PreparationsCationsantigen CYFRA21.1Antigens, NeoplasmKeratin-19

Autor:innen und Institutionen

  • Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineerin…
  • Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea. Electronic address: jinylee@skku.edu.

Zitieren

APA

Wang, X., Leng, D., Li, F., Liu, L., Ren, X., Lee, J. Y., Ju, H., & Wei, Q. (2023). A split-type photoelectrochemical immunosensing platform based on atom-efficient cation exchange for physiological monitoring. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.341340

Vancouver

Wang X, Leng D, Li F, Liu L, Ren X, Lee JY, et al. A split-type photoelectrochemical immunosensing platform based on atom-efficient cation exchange for physiological monitoring. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.341340

BibTeX
@article{Wang2023,
  author = {Wang, Xue and Leng, Dongquan and Li, Faying and Liu, Lei and Ren, Xiang and Lee, Jin Yong and Ju, Huangxian and Wei, Qin},
  title = {A split-type photoelectrochemical immunosensing platform based on atom-efficient cation exchange for physiological monitoring},
  journal = {Analytica Chimica Acta},
  year = {2023},
  doi = {10.1016/j.aca.2023.341340}
}
Kostenlos starten →