Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19
Analytica Chimica Acta · 2023
DOI: 10.1016/j.aca.2023.341326 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Shalu Yadav und 3 weiteren Autor:innen. Beteiligte Einrichtung: CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Gh…. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal Nanoparticles, COVID-19, Graphite. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Council of Scientific and Industrial Research, India, Department of Science and Technology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India. Electronic address: khan.raju@gmail.com.
Förderung
- Council of Scientific and Industrial Research, India
- Department of Science and Technology, Ministry of Science and Technology, India
Zitieren
APA
Yadav, S., Sadique, M. A., Ranjan, P., & Khan, R. (2023). Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.341326
Vancouver
Yadav S, Sadique MA, Ranjan P, Khan R. Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.341326
BibTeX
@article{Yadav2023,
author = {Yadav, Shalu and Sadique, Mohd Abubakar and Ranjan, Pushpesh and Khan, Raju},
title = {Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19},
journal = {Analytica Chimica Acta},
year = {2023},
doi = {10.1016/j.aca.2023.341326}
}
EUVIMED