Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves
Analytica Chimica Acta · 2023
DOI: 10.1016/j.aca.2023.341070 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Rohit Mishra und 13 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; School of Physical Sciences, Dublin City Uni…. Hauptthemen laut MEDLINE: Microfluidic Analytical Techniques, Nucleic Acids. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Science Foundation Ireland, Fraunhofer-Gesellschaft.
Abstract (Originalsprache)
By virtue of its ruggedness, portability, rapid processing times, and ease-of-use, academic and commercial interest in centrifugal microfluidic systems has soared over the last decade. A key advantage of the LoaD platform is the ability to automate laboratory unit operations (LUOs) (mixing, metering, washing etc.) to support direct translation of 'on-bench' assays to 'on-chip'. Additionally, the LoaD requires just a low-cost spindle motor rather than specialized and expensive microfluidic pumps. Furthermore, when flow control (valves) is implemented through purely rotational changes in this same spindle motor (rather than using additional support instrumentation), the LoaD offers the potential to be a truly portable, low-cost and accessible platform. Current rotationally controlled valves are typically opened by sequentially increasing the disc spin-rate to a specific opening frequency. However, due lack of manufacturing fidelity these specific opening frequencies are better described as spin frequency 'bands'. With low-cost motors typically having a maximum spin-rate of 6000 rpm (100 Hz), using this 'analogue' approach places a limitation on the number of valves, which can be serially actuated thus limiting the number of LUOs that can be automated. In this work, a novel flow control scheme is presented where the sequence of valve actuation is determined by architecture of the disc while its timing is governed by freely programmable 'digital' pulses in its spin profile. This paradigm shift to 'digital' flow control enables automation of multi-step assays with high reliability, with full temporal control, and with the number of LUOs theoretically only limited by available space on the disc. We first describe the operational principle of these valves followed by a demonstration of the capability of these valves to automate complex assays by screening tomato leaf samples against plant pathogens. Reagents and lysed sample are loaded on-disc and then, in a fully autonomous fashion using only spindle-motor control, the complete assay is automated. Amplification and fluorescent acquisition take place on a custom spin-stand enabling the generation of real-time LAMP amplification curves using custom software. To prevent environmental contamination, the entire discs are sealed from atmosphere following loading with internal venting channels permitting easy movement of liquids about the disc. The disc was successfully used to detect the presence of thermally inactivated Clavibacter michiganensis. Michiganensis (CMM) bacterial pathogen on tomato leaf samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; School of Physical Sciences, Dublin City University, Dublin, Ireland; National Centre for Sensor Research (NCSR),…
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland.
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; School of Physical Sciences, Dublin City University, Dublin, Ireland; School of Mechanical and Manufacturing Engin…
- National Institute of Biology, Ljubljana, Slovenia.
- School of Physical Sciences, Dublin City University, Dublin, Ireland.
- Wageningen University Research, Wageningen, the Netherlands.
Förderung
- European Commission
- Science Foundation Ireland
- Fraunhofer-Gesellschaft
Zitieren
APA
Mishra, R., Julius, L. A., Condon, J., Pavelskopfa, P., Early, P. L., Dorrian, M., Mrvova, K., Henihan, G., Mangwanya, F., Dreo, T., Ducrée, J., Macdonald, N. P., Schoen, C., & Kinahan, D. J. (2023). Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.341070
Vancouver
Mishra R, Julius LA, Condon J, Pavelskopfa P, Early PL, Dorrian M, et al. Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.341070
BibTeX
@article{Mishra2023,
author = {Mishra, Rohit and Julius, Lourdes An and Condon, Jack and Pavelskopfa, Patricija and Early, Philip L and Dorrian, Matthew and Mrvova, Katarina and Henihan, Grace and Mangwanya, Faith and Dreo, Tanya and Ducrée, Jens and Macdonald, Niall P and Schoen, Cor and Kinahan, David J},
title = {Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves},
journal = {Analytica Chimica Acta},
year = {2023},
doi = {10.1016/j.aca.2023.341070}
}
EUVIMED