Long-term repeatability improvement using beam intensity distribution for laser-induced breakdown spectroscopy
Analytica Chimica Acta · 2023-04 · 1251 · 341004
DOI: 10.1016/j.aca.2023.341004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-04. Verfasst von Jiacen Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Power System Operation and Control, International Joint Laboratory on Low Carbon Clean Energy Innovation, Department of Energ…. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The relatively low measurement repeatability has long been considered as a major obstacle to the widespread use and commercialization of laser-induced breakdown spectroscopy (LIBS). Although many efforts have been made to improve the signal repeatability in the short term, how to improve the long-term signal repeatability is critical in practical applications and has rarely been studied. Moreover, the mechanisms behind the degradation of long-term repeatability are not fully revealed. This study proposes a new method to improve the long-term repeatability of LIBS measurement, which modifies the spectral intensity based on laser beam intensity distribution. It first pre-processes the beam intensity distribution profiles and spectral intensity. Then the relationship between the relative deviations of beam and spectral intensities is modelled using Partial Least Squares Regression (PLSR). The proposed method was tested on copper and silicon samples, and the spectra and laser beam intensity distribution were recorded for more than thirty days. Day-to-day variations in beam intensity distribution were observed. Such variations can lead to changes in spectral intensity, resulting in degraded signal repeatability. By modifying the spectral intensity, the long-term signal repeatability was improved. Specifically, in terms of day-mean spectral intensity, the valid correction rates were above 70% for both of copper silicon sample in most cases. Long-term RSD decreased from ∼13.5% to ∼4% for copper and decreased from ∼10.7% to 6.5% for silicon sample. These results indicate that the proposed method provides a viable method for improving the long-term repeatability of LIBS measurement.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Power System Operation and Control, International Joint Laboratory on Low Carbon Clean Energy Innovation, Department of Energy and Power Engineering, Tsinghua University, Beijing, 100084, China.
- State Key Laboratory of Power System Operation and Control, International Joint Laboratory on Low Carbon Clean Energy Innovation, Department of Energy and Power Engineering, Tsinghua University, Beijing, 100084, China;…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Liu, J., Song, W., Gu, W., Hou, Z., Kou, K., & Wang, Z. (2023). Long-term repeatability improvement using beam intensity distribution for laser-induced breakdown spectroscopy. Analytica Chimica Acta, 1251, 341004. https://doi.org/10.1016/j.aca.2023.341004
Vancouver
Liu J, Song W, Gu W, Hou Z, Kou K, Wang Z. Long-term repeatability improvement using beam intensity distribution for laser-induced breakdown spectroscopy. Analytica Chimica Acta. 2023;1251:341004. doi:10.1016/j.aca.2023.341004
BibTeX
@article{Liu2023,
author = {Liu, Jiacen and Song, Weiran and Gu, Weilun and Hou, Zongyu and Kou, Kaikai and Wang, Zhe},
title = {Long-term repeatability improvement using beam intensity distribution for laser-induced breakdown spectroscopy},
journal = {Analytica Chimica Acta},
year = {2023},
volume = {1251},
pages = {341004},
doi = {10.1016/j.aca.2023.341004}
}
EUVIMED