Bidirectional motivated bimodal isothermal strand displacement amplifier with a table tennis-like movement for the ultrasensitive fluorescent and colorimetric detection of depression-related microRNA
Analytica Chimica Acta · 2023
DOI: 10.1016/j.aca.2023.340894 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Xiaoming Kong und 10 weiteren Autor:innen. Beteiligte Einrichtung: Affiliated Psychological Hospital of Anhui Medical University, Anhui Mental Health Center, Hefei Fourth People's Hospital, 316 Huangshan Road, Hefei,…. Hauptthemen laut MEDLINE: Biosensing Techniques, Major Depressive Disorder, MicroRNAs. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Anhui Medical University, University Natural Science Research Project of Anhui Province, Key Technologies Research and Development Program.
Themen: Depression
Abstract (Originalsprache)
Kein Abstract verfügbar.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Affiliated Psychological Hospital of Anhui Medical University, Anhui Mental Health Center, Hefei Fourth People's Hospital, 316 Huangshan Road, Hefei, 230022, PR China.
- School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China.
- School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China. Electronic address: 15205519023@163.com.
- Department of Geriatric Endocrinology, The First Affiliated Hospital of Anhui Medical University, 218 Jixi Road, Hefei, 230022, PR China. Electronic address: syan956@163.com.
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, 230009, Anhui, PR China. Electronic address: jgxu0816@163.com.
Förderung
- Anhui Medical University
- University Natural Science Research Project of Anhui Province
- Key Technologies Research and Development Program
Zitieren
APA
Kong, X., Wang, J., Lv, S., Wang, C., Hong, H., Xie, P., Guo, Y., Zhu, N., Qin, P., Sun, Y., & Xu, J. (2023). Bidirectional motivated bimodal isothermal strand displacement amplifier with a table tennis-like movement for the ultrasensitive fluorescent and colorimetric detection of depression-related microRNA. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.340894
Vancouver
Kong X, Wang J, Lv S, Wang C, Hong H, Xie P, et al. Bidirectional motivated bimodal isothermal strand displacement amplifier with a table tennis-like movement for the ultrasensitive fluorescent and colorimetric detection of depression-related microRNA. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.340894
BibTeX
@article{Kong2023,
author = {Kong, Xiaoming and Wang, Junfeng and Lv, Siwen and Wang, Chen and Hong, Hong and Xie, Pengyv and Guo, Yv and Zhu, Nannan and Qin, Panzhu and Sun, Yan and Xu, Jianguo},
title = {Bidirectional motivated bimodal isothermal strand displacement amplifier with a table tennis-like movement for the ultrasensitive fluorescent and colorimetric detection of depression-related microRNA},
journal = {Analytica Chimica Acta},
year = {2023},
doi = {10.1016/j.aca.2023.340894}
}
EUVIMED