EUVIMEDEUVIMED entdecken
Crossref

Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format

Xiaxia Wei, Xirui Chen, Zilong Liu, Ge Xu, Guoxin Chen, Xiangkai Lin, Wenchao Zhan, Xiaolin Huang, Yonghua Xiong

Analytica Chimica Acta · 2023-03 · 1247 · 340869

DOI: 10.1016/j.aca.2023.340869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-03. Verfasst von Xiaxia Wei und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China; School of Food Science and Technology, Nanchang Un…. Hauptthemen laut MEDLINE: Luminescence, Coloring Agents. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangxi Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Organic fluorescein dye-embedded fluorescent microspheres (FMs) are currently the most established commercially fluorescent markers, and they have been widely used to improve the sensitivity of immunochromatography assay (ICA). However, these FMs have natural defects, such as the aggregation-caused quenching effect and small Stokes shift, which are not conducive to improving the detection performance of ICA. Herein, two green emitted FMs, namely aggregation-induced emission FMs (AIEFMs) and fluorescein isothiocyanate FMs (FITCFMs), were prepared by swelling the AIE luminogens and FITC dyes into the carboxyl group-modified polystyrene microspheres. The average diameters of AIEFMs and FITCFMs were 350 and 450 nm, respectively. Compared with FITCFMs, the AIEFMs exhibited stronger fluorescence intensity and a larger Stokes shift. These two FMs were used as the labeling markers of ICA for procalcitonin (PCT) detection with the sandwich format. Among them, AIEFM-ICA showed dynamic linear detection of PCT from 7.6 pg mL-1 to 125 ng mL-1 with the limit of detection (LOD) at 3.8 pg mL-1. These values were remarkably superior to those of FITCFM-ICA (linear range from 61 pg mL-1 to 62.5 ng mL-1 and LOD value at 60 pg mL-1). Furthermore, the average recoveries of the intra- and inter-assays of AIEFM-ICA ranged from 86% to 112%, with coefficients of variation ranging from 1.2% to 8.8%, indicating accuracy and precision for PCT quantitative detection. Additionally, the reliability of the developed AIEFM-ICA was further assessed by analyzing 30 real serum samples from systemic inflammatory response by infectious diseases, and the results showed good agreement with the chemiluminescence immunoassay. In conclusion, compared with traditional FITCFMs, green emitted AIEFMs as a novel fluorescent label, exhibits greater potential to enhance the detection performance of the ICA platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LuminescenceColoring AgentsMicrospheresReproducibility of ResultsChromatography, AffinityFluoresceinsImmunoassay

Stichwörter der Autor:innen

Aggregation-induced luminescence microspheresDetection performanceImmunochromatography assayOrganic fluorescein dye-embedded microspheresProcalcitonin

Substanzen

Coloring AgentsFluoresceins

Autor:innen und Institutionen

  • State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China; School of Food Science and Technology, Nanchang University, Nanchang, 330031, China.
  • School of Food Science and Engineering, Hainan University, Haikou, 570228, China.
  • State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China; School of Food Science and Technology, Nanchang University, Nanchang, 330031, China. Electronic address: hxl19880503@163…
  • State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China; School of Food Science and Technology, Nanchang University, Nanchang, 330031, China; Jiangxi-OAI Joint Research Institut…

Förderung

  • Natural Science Foundation of Jiangxi Province
  • National Natural Science Foundation of China

Zitieren

APA

Wei, X., Chen, X., Liu, Z., Xu, G., Chen, G., Lin, X., Zhan, W., Huang, X., & Xiong, Y. (2023). Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format. Analytica Chimica Acta, 1247, 340869. https://doi.org/10.1016/j.aca.2023.340869

Vancouver

Wei X, Chen X, Liu Z, Xu G, Chen G, Lin X, et al. Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format. Analytica Chimica Acta. 2023;1247:340869. doi:10.1016/j.aca.2023.340869

BibTeX
@article{Wei2023,
  author = {Wei, Xiaxia and Chen, Xirui and Liu, Zilong and Xu, Ge and Chen, Guoxin and Lin, Xiangkai and Zhan, Wenchao and Huang, Xiaolin and Xiong, Yonghua},
  title = {Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format},
  journal = {Analytica Chimica Acta},
  year = {2023},
  volume = {1247},
  pages = {340869},
  doi = {10.1016/j.aca.2023.340869}
}
Kostenlos starten →