EUVIMEDEUVIMED entdecken
Crossref

How to choose proper magnetic particles for bioaffinity interactions? The case for immobilised glyconanoconjugate

Veronika Vrablova, Anna Blsakova, Lenka Lorencova, Jozef Kollar, Alica Vikartovska, Peter Kasak, Jan Tkac

Analytica Chimica Acta · 2023

DOI: 10.1016/j.aca.2023.340794 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023. Verfasst von Veronika Vrablova und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38, Bratislava, Slovakia. Hauptthemen laut MEDLINE: Magnetics, Nanoconjugates, Antigens, Tumor-Associated, Carbohydrate. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: European Regional Development Fund, Ministry of Education Science Research and Sport of the Slovak Republic, Qatar University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, an assay for detection of the cancer biomarker Thomsen-nouvelle (Tn) antigen on the ELISA plates format was designed and developed. The effects of size and the interfacial density of the negative charge of magnetic beads (MBs) on the specific sensitivity of the bioaffinity interaction were studied. In particular, glyconanoconjugate, i.e. glycan Tn antigen conjugated to bovine serum albumin (BSA) was covalently immobilised on MBs for the bioaffinity detection of anti-Tn antibodies as cancer biomarkers. Six different MBs were used in the study, i.e. carboxy-modified MBs of 250 nm, 500 nm, 1000 nm and 2800 nm and epoxy-modified MBs of 2800 nm and 4500 nm. In order to evaluate which MBs are the best suited for detection of the analyte anti-Tn antibodies, sensitivities of detection (slopes from calibration curves) were calculated. Next, specific sensitivities were calculated for each type of MBs as a ratio of sensitivity of detection to the mass of MBs. From zeta potential ζ for each type of MBs, the interfacial charge density on MBs was calculated, expressed as the density of zeta potential ζd (ratio of zeta potential to surface area of MBs, i.e. ζd = ζ/A). Then, we evaluated the effect of size and ζd on the specific sensitivity of detection of anti-Tn antibodies in order to understand the immobilisation process on nanoscale. We also identified an optimal value of ζd on MBs; this was essential to achieve highly sensitive detection of the analyte, which made it possible to attain limit of detection (LOD) of (0.31 ± 0.01) ng mL-1 or (2.10 ± 0.04) pM for analyte detection. In addition, the optimal assay configuration was highly selective and enabled reliable detection of the analyte in human serum with a recovery index in the range of 102-104%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagneticsNanoconjugatesAntigens, Tumor-Associated, CarbohydrateHumansMagnetic PhenomenaSerum Albumin, Bovine

Stichwörter der Autor:innen

Aberrant glycansAntibodies against aberrant glycansMagnetic beadsMagnetic separationSuspension assay

Substanzen

Serum Albumin, BovineNanoconjugatesTn antigenAntigens, Tumor-Associated, Carbohydrate

Autor:innen und Institutionen

  • Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38, Bratislava, Slovakia.
  • Polymer Institute, Slovak Academy of Sciences, Dubravska cesta 9, 845 41, Bratislava, Slovakia.
  • Center for Advanced Materials, Qatar University, P.O. Box 2713, Doha, Qatar. Electronic address: peter.kasak@qu.edu.qa.
  • Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38, Bratislava, Slovakia. Electronic address: Jan.Tkac@savba.sk.

Förderung

  • European Regional Development Fund
  • Ministry of Education Science Research and Sport of the Slovak Republic
  • Qatar University
  • Agentúra na Podporu Výskumu a Vývoja
  • Vedecká Grantová Agentúra MŠVVaŠ SR a SAV

Zitieren

APA

Vrablova, V., Blsakova, A., Lorencova, L., Kollar, J., Vikartovska, A., Kasak, P., & Tkac, J. (2023). How to choose proper magnetic particles for bioaffinity interactions? The case for immobilised glyconanoconjugate. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2023.340794

Vancouver

Vrablova V, Blsakova A, Lorencova L, Kollar J, Vikartovska A, Kasak P, et al. How to choose proper magnetic particles for bioaffinity interactions? The case for immobilised glyconanoconjugate. Analytica Chimica Acta. 2023. doi:10.1016/j.aca.2023.340794

BibTeX
@article{Vrablova2023,
  author = {Vrablova, Veronika and Blsakova, Anna and Lorencova, Lenka and Kollar, Jozef and Vikartovska, Alica and Kasak, Peter and Tkac, Jan},
  title = {How to choose proper magnetic particles for bioaffinity interactions? The case for immobilised glyconanoconjugate},
  journal = {Analytica Chimica Acta},
  year = {2023},
  doi = {10.1016/j.aca.2023.340794}
}
Kostenlos starten →