EUVIMEDEUVIMED entdecken
Crossref

Melting curve analysis-based multiplex real-time PCR assay mediated by universal primers for detection of multiple virus targets

Zixuan Meng, Pei Nan, Dan Wen, Xuanyi Ren, Yonghou Jiang

Analytical Biochemistry · 2027-02 · 721 · 116287

DOI: 10.1016/j.ab.2026.116287 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2027-02. Verfasst von Zixuan Meng und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Zhejiang Province Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiplex quantitative real-time PCR (M-qPCR) is increasingly becoming a commonly used technique in molecular detection of pathogens due to its advantages in quantification and throughput. However, imbalanced amplification is still a potential problem affecting performance of M-qPCR assays. In this study, a novel universal primer multiplex quantitative real-time PCR (UP-M-qPCR) assay using EvaGreen and melting curve analysis was developed, using five swine diarrhea-related viruses as a case study. UPs and the chimeric primers (CPs) were introduced in this assay for sequential virus-specific and universal amplification to produce large amounts of amplicons for five target viruses with similar efficiency. Subsequent melting analysis of the amplicons displayed five distinguishable target-specific melting peaks with characteristic melting temperatures (Tms), while no non-specific amplification or melting peak was observed for five non-target viruses. The assay achieved a limit of detection (LOD) of 5 copies/μL of viral plasmids in various settings including high-background co-infections. Meanwhile, the coefficient of variation of Tm value and Ct values fell within 0-0.57% and 0.12-4.37% respectively, suggesting good repeatability of the assay. The UP-M-qPCR and corresponding singleplex qPCR were used in parallel to detect field samples for five viruses. The diagnostic sensitivity and specificity of the UP-M-qPCR were 90.9-100% and 99.4-100%, respectively, with a kappa value of 0.95-1, indicating good consistency. Overall, this study presents a melting curve analysis-based UP-M-qPCR assay, enabling the concurrent detection of multiple viruses with high sensitivity and specificity, which provides a technical platform easily adaptable for multiple pathogens detection.

Schlagwörter

Stichwörter der Autor:innen

EvaGreenMelting curve analysisMultiplex quantitative real-time PCRUniversal primerVirus detection

Autor:innen und Institutionen

  • College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
  • College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China. Electronic address: yonghoujiang@zstu.edu.cn.

Förderung

  • Zhejiang Province Natural Science Foundation

Zitieren

APA

Meng, Z., Nan, P., Wen, D., Ren, X., & Jiang, Y. (2027). Melting curve analysis-based multiplex real-time PCR assay mediated by universal primers for detection of multiple virus targets. Analytical Biochemistry, 721, 116287. https://doi.org/10.1016/j.ab.2026.116287

Vancouver

Meng Z, Nan P, Wen D, Ren X, Jiang Y. Melting curve analysis-based multiplex real-time PCR assay mediated by universal primers for detection of multiple virus targets. Analytical Biochemistry. 2027;721:116287. doi:10.1016/j.ab.2026.116287

BibTeX
@article{Meng2027,
  author = {Meng, Zixuan and Nan, Pei and Wen, Dan and Ren, Xuanyi and Jiang, Yonghou},
  title = {Melting curve analysis-based multiplex real-time PCR assay mediated by universal primers for detection of multiple virus targets},
  journal = {Analytical Biochemistry},
  year = {2027},
  volume = {721},
  pages = {116287},
  doi = {10.1016/j.ab.2026.116287}
}
Kostenlos starten →