EUVIMEDEUVIMED entdecken
Crossref

Development of immunoassay methods for ricin and application in the OPCW international proficiency test

Tao Zhang, Zhongfang Xing, Xiujie Liu, Zhibin Shu, Wenwen Xin, Shilei Liu

Analytical Biochemistry · 2026

DOI: 10.1016/j.ab.2026.116234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2026. Verfasst von Tao Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing, 102299, China. Hauptthemen laut MEDLINE: Ricin, Laboratory Proficiency Testing, Chemical Warfare Agents. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Organisation for the Prohibition of Chemical Weapons (OPCW) organizes the annual Trial Biotoxins Proficiency Test (ToxPT) to implement standardized and transparent evaluation on the technical proficiency of laboratories applying for or retaining official designation for biotoxin analysis. Laboratories are required to pass all relevant ToxPT events to prove sustained detection capability. Launched in August 2025, the Second Trial ToxPT centered on ricin detection and marked the first inclusion of high-molecular-weight protein toxins within an OPCW proficiency test. This study aimed to construct an immunological detection platform for ricin using conventional analytical methods, including WB and ELISA, and to evaluate their application performance in the Second Trial ToxPT. By optimizing the experimental parameters of immunoassays-including antibody coating concentration, blocking buffer selection, and working concentration of enzyme-labeled secondary antibody-we successfully established WB and sandwich ELISA methods for ricindetection. As a quantitative method, the ELISA assay employed four-parameter nonlinear regression to fit the standard curve and derive the standard equation, with a correlation coefficient (R2) of 0.9974, a limit of detection (LOD) of 1 ng/mL, a limit of quantitation (LOQ) of 7 ng/mL, and a broad quantitative range of 7-400 ng/mL. When applied to sample analysis in the second trial ToxPT, the obtained results were accurate and consistent with official reference data. These validated methods exhibit high reliability for routine ricin detection and lay a solid technical foundation for laboratories to sustain their biotoxin analysis accreditation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RicinLaboratory Proficiency TestingChemical Warfare AgentsEnzyme-Linked Immunosorbent AssayLimit of Detection

Stichwörter der Autor:innen

Immunological detectionOPCW proficiency testRibosome-inactivating proteinsRicin

Substanzen

RicinChemical Warfare Agents

Autor:innen und Institutionen

  • State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing, 102299, China.
  • State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China. Electronic address: xinww@hotmail.com.
  • State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing, 102299, China. Electronic address: liu_shilei@lacricd.com.

Zitieren

APA

Zhang, T., Xing, Z., Liu, X., Shu, Z., Xin, W., & Liu, S. (2026). Development of immunoassay methods for ricin and application in the OPCW international proficiency test. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2026.116234

Vancouver

Zhang T, Xing Z, Liu X, Shu Z, Xin W, Liu S. Development of immunoassay methods for ricin and application in the OPCW international proficiency test. Analytical Biochemistry. 2026. doi:10.1016/j.ab.2026.116234

BibTeX
@article{Zhang2026,
  author = {Zhang, Tao and Xing, Zhongfang and Liu, Xiujie and Shu, Zhibin and Xin, Wenwen and Liu, Shilei},
  title = {Development of immunoassay methods for ricin and application in the OPCW international proficiency test},
  journal = {Analytical Biochemistry},
  year = {2026},
  doi = {10.1016/j.ab.2026.116234}
}
Kostenlos starten →