Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads

Jeffrey M Schaub, Isabel Ojeda, Quinn A Best, Qiaoqiao Ruan

Analytical Biochemistry · 2026-10 · 717 · 116188

DOI: 10.1016/j.ab.2026.116188 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Analytical Biochemistry, 2026-10. Verfasst von Jeffrey M Schaub und 3 weiteren Autor:innen. Beteiligte Einrichtung: Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL, 60064-6016, United States. Hauptthemen laut MEDLINE: Antibody Affinity. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Abbott Diagnostics.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Some of the most well-characterized interactions between biomolecules occur between antibodies and their respective antigens; these interactions are the backbone of the modern pharmaceutical and diagnostic industries. Solution equilibrium titration (SET) is the gold standard method for measuring affinities between biomolecules, where a fixed concentration of analyte is titrated with a variable concentration of titrant. However, SET measurements require innate or external signal differences to distinguish between free and bound analyte. Here, we evaluated a solution-phase reaction, solid-phase detection (SRSD) method that probes the fraction of free analyte in an equilibrium titration with titrant-coated magnetic beads to estimate the apparent binding affinity. We comprehensively compared SRSD against traditional methods using two different antibody-antigen pairs and relevant controls. We show that SRSD produces affinity measurements of the same order of magnitude as those measured by well-established label-free kinetic (SPR) and solution-phase equilibrium (SET) approaches. We anticipate that the SRSD method may be of general interest for affinity estimation, as it can be performed with unpurified analytes in complex mixtures. However, this method cannot be assumed to be generally valid or interchangeable across all systems, as the study illustrates system-specific, situational utility when appropriate validation controls are implemented.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibody AffinitySolutionsKineticsTitrimetry

Stichwörter der Autor:innen

AffinityAntibodyAntigenProtein-protein interaction

Substanzen

Solutions

Autor:innen und Institutionen

  • Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL, 60064-6016, United States.
  • Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL, 60064-6016, United States. Electronic address: qiaoqiao.ruan@abbott.com.

Förderung

  • Abbott Diagnostics

Zitieren

APA

Schaub, J. M., Ojeda, I., Best, Q. A., & Ruan, Q. (2026). Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads. Analytical Biochemistry, 717, 116188. https://doi.org/10.1016/j.ab.2026.116188

Vancouver

Schaub JM, Ojeda I, Best QA, Ruan Q. Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads. Analytical Biochemistry. 2026;717:116188. doi:10.1016/j.ab.2026.116188

BibTeX
@article{Schaub2026,
  author = {Schaub, Jeffrey M and Ojeda, Isabel and Best, Quinn A and Ruan, Qiaoqiao},
  title = {Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads},
  journal = {Analytical Biochemistry},
  year = {2026},
  volume = {717},
  pages = {116188},
  doi = {10.1016/j.ab.2026.116188}
}
Kostenlos starten →