EUVIMEDEUVIMED entdecken
Crossref

Molecularly imprinted polymers-ZnS quantum dots based composite sensor for optical detection of chlorogenic acid

Himshweta, Neelam Verma, Nitu Trehan, Minni Singh

Analytical Biochemistry · 2025-07 · 702 · 115846

DOI: 10.1016/j.ab.2025.115846 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2025-07. Verfasst von Himshweta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biosensor Development Group, Department of Biotechnology & Food Technology, Punjabi University Patiala, 147002, Punjab, India. Electronic address: hi…. Hauptthemen laut MEDLINE: Quantum Dots, Chlorogenic Acid, Zinc Compounds, Sulfides. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 102 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chlorogenic acid (CGA), a key phenolic acid found in coffee, fruits, vegetables, and herbs, has significant pharmacological activities, necessitating its accurate detection in complex matrices. In this study, an organic acrylate molecularly imprinted polymers-chitosan modified zinc sulphide quantum dots/polydopamine (MIPs-CS:ZnS QDs/PDA) based composite sensor for the detection of CGA has been designed. In MIPs shell, CGA served as template and 4-vinylpyridine and methacrylic acid as functional monomers, azobisisobutyronitrile acting as the initiator and ethylene glycol dimethacrylate as the cross-linker. Chitosan was incorporated to enhance the stability of ZnS QDs, while polydopamine was introduced during polymerization to improve adhesion and the selectivity of MIPs for CGA. Under ideal conditions, the composite sensor had shown a linear range of 0.02-11 μg/mL with detection limit of 8.9 × 10-3 μg/mL. The composite sensor showed imprinting factor of 6.3, and response time of 12 min. The sensor demonstrated good selectivity towards CGA, in the presence of interfering agents. Composite sensor was successfully applied to detect CGA in plant extracts, coffee and fruit juices, with recovery ranges from 88.93 to 98.49 %. The MIPs-CS:ZnS QDs/PDA composite sensor offers a simple and robust approach for CGA detection in real samples without requiring pre-treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quantum DotsChlorogenic AcidZinc CompoundsSulfidesMolecularly Imprinted PolymersPolymersMolecular ImprintingCoffeeChitosanLimit of DetectionIndolesFruit and Vegetable Juices

Stichwörter der Autor:innen

Chlorogenic acidFluorescenceMolecularly imprinted polymersQuenchingZnS quantum dots

Substanzen

Chlorogenic AcidZinc Compoundszinc sulfideSulfidesMolecularly Imprinted PolymersPolymerspolydopamineCoffeeChitosanIndoles

Autor:innen und Institutionen

  • Biosensor Development Group, Department of Biotechnology & Food Technology, Punjabi University Patiala, 147002, Punjab, India. Electronic address: himshweta85@gmail.com.
  • Biosensor Development Group, Department of Biotechnology & Food Technology, Punjabi University Patiala, 147002, Punjab, India. Electronic address: verma.neelam2@gmail.com.
  • Department of Biotechnology, Mata Gujri College Fatehgarh Sahib, 140407, Punjab, India. Electronic address: neetubiotech@matagujricollege.org.
  • Functional Food and Nanotechnology Group, Department of Biotechnology & Food Technology, Punjabi University Patiala, 147002, Punjab, India. Electronic address: minnisingh@pbi.ac.in.

Zitieren

APA

Himshweta, Verma, N., Trehan, N., & Singh, M. (2025). Molecularly imprinted polymers-ZnS quantum dots based composite sensor for optical detection of chlorogenic acid. Analytical Biochemistry, 702, 115846. https://doi.org/10.1016/j.ab.2025.115846

Vancouver

Himshweta, Verma N, Trehan N, Singh M. Molecularly imprinted polymers-ZnS quantum dots based composite sensor for optical detection of chlorogenic acid. Analytical Biochemistry. 2025;702:115846. doi:10.1016/j.ab.2025.115846

BibTeX
@article{Himshweta2025,
  author = {Himshweta and Verma, Neelam and Trehan, Nitu and Singh, Minni},
  title = {Molecularly imprinted polymers-ZnS quantum dots based composite sensor for optical detection of chlorogenic acid},
  journal = {Analytical Biochemistry},
  year = {2025},
  volume = {702},
  pages = {115846},
  doi = {10.1016/j.ab.2025.115846}
}
Kostenlos starten →