Microfluidic bead-based biosensor: Ultrasensitive ctDNA detection based on duplex-functional split-DNAzyme and dendritic enzyme-free signal amplification
Analytical Biochemistry · 2024-04 · 687 · 115457
DOI: 10.1016/j.ab.2024.115457 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Biochemistry, 2024-04. Verfasst von Xin Fu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Eng…. Hauptthemen laut MEDLINE: DNA, Catalytic, Epstein-Barr Virus Infections, Biosensing Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Hunan Provincial Natural Science Foundation.
Abstract (Originalsprache)
Circulating tumor DNA (ctDNA) is a crucial cancer biomarker for early or noninvasive monitoring, which is essential for developing ultrasensitive and selective assays in cancer diagnosis and treatment. Herein, a cascade signal amplification of duplex-functional split-DNAzyme and dendritic probes was proposed for ultrasensitive and specific detection of nasopharyngeal carcinoma-associated Epstein-Barr virus (EBV) DNA on microfluidic microbead array chips. With the assistance of Pb2+, the duplex-functional split-DNAzyme recognizes EBV DNA and then rapidly cleaves the substrate strand. Subsequently, the released target could be recycled, and its exposed capture probe, triggered the dendritic enzyme-free signal amplification. As the enhanced mass transfer capability, target recycling, and dendritic DNA structure signal amplification inherent to microfluidic bead arrays were integrated, it achieved an excellent detection limit of 0.36 fM and a wide linear range of 1 fM∼103 fM. Further, it was applied to content detect simulated samples of EBV DNA, recovery ranged from 97.2 % to 108.1 %, and relative standard deviation (RSD) from 3.3 % to 5.9 %, exhibiting satisfactory recovery results. The developed microfluidic biosensor was a high-sensitivity and anti-interference system for ctDNA analysis, with minimal reagent volumes (microlitres) required. Thus, it is a promising platform for ctDNA at the lowest level at their earliest incidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China.
- Hunan Provincial Key Laboratory of Environmental Catalysis and Waste Recycling, College of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan, 411104, China. Electronic address: mzhang_he@126.c…
Förderung
- National Natural Science Foundation of China
- Hunan Provincial Natural Science Foundation
Zitieren
APA
Fu, X., Yang, M., Zhang, H., Wang, Q., Fu, Y., & Liu, Q. (2024). Microfluidic bead-based biosensor: Ultrasensitive ctDNA detection based on duplex-functional split-DNAzyme and dendritic enzyme-free signal amplification. Analytical Biochemistry, 687, 115457. https://doi.org/10.1016/j.ab.2024.115457
Vancouver
Fu X, Yang M, Zhang H, Wang Q, Fu Y, Liu Q. Microfluidic bead-based biosensor: Ultrasensitive ctDNA detection based on duplex-functional split-DNAzyme and dendritic enzyme-free signal amplification. Analytical Biochemistry. 2024;687:115457. doi:10.1016/j.ab.2024.115457
BibTeX
@article{Fu2024,
author = {Fu, Xin and Yang, Mei and Zhang, He and Wang, Qing and Fu, Yu and Liu, Qiong},
title = {Microfluidic bead-based biosensor: Ultrasensitive ctDNA detection based on duplex-functional split-DNAzyme and dendritic enzyme-free signal amplification},
journal = {Analytical Biochemistry},
year = {2024},
volume = {687},
pages = {115457},
doi = {10.1016/j.ab.2024.115457}
}
EUVIMED