Method for detecting rare differences between two LC-MS runs
Analytical Biochemistry · 2023-08 · 674 · 115211
DOI: 10.1016/j.ab.2023.115211 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Biochemistry, 2023-08. Verfasst von Zhongqi Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Process Development, Amgen Inc., One Amgen Center Drive, Thousand Oaks, CA, 91320, USA. Electronic address: zzhang@amgen.com. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Amgen.
Abstract (Originalsprache)
LC-MS based multi-attribute methods (MAM) have drawn substantial attention due to their capability of simultaneously monitoring a large number of quality attributes of a biopharmaceutical product. For successful implementation of MAM, it is usually considered a requirement that the method is capable of detecting any new or missing peaks in the sample when compared to a control. Comparing a sample to a control for rare differences is also commonly practiced in many fields for investigational purpose. Because MS signal variability differs greatly between signals of different intensities, this type of comparison is often challenging, especially when the comparison is made without enough replicates. In this report we describe a statistical method for detecting rare differences between two very similar samples without replicate analyses. The method assumes that an overwhelming majority of components have equivalent abundance between the two samples, and signals with similar intensities have similar relative variability. By analyzing several monoclonal antibody peptide mapping datasets, we demonstrated that the method is suitable for new-peak detection for MAM as well as for other applications when rare differences between two samples need to be detected. The method greatly reduced false positive rate without a significant increase of false negative rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Process Development, Amgen Inc., One Amgen Center Drive, Thousand Oaks, CA, 91320, USA. Electronic address: zzhang@amgen.com.
- Process Development, Amgen Inc., One Amgen Center Drive, Thousand Oaks, CA, 91320, USA.
Förderung
- Amgen
Zitieren
APA
Zhang, Z., Richardson, J., & Shah, B. (2023). Method for detecting rare differences between two LC-MS runs. Analytical Biochemistry, 674, 115211. https://doi.org/10.1016/j.ab.2023.115211
Vancouver
Zhang Z, Richardson J, Shah B. Method for detecting rare differences between two LC-MS runs. Analytical Biochemistry. 2023;674:115211. doi:10.1016/j.ab.2023.115211
BibTeX
@article{Zhang2023,
author = {Zhang, Zhongqi and Richardson, Jason and Shah, Bhavana},
title = {Method for detecting rare differences between two LC-MS runs},
journal = {Analytical Biochemistry},
year = {2023},
volume = {674},
pages = {115211},
doi = {10.1016/j.ab.2023.115211}
}
EUVIMED