EUVIMEDEUVIMED entdecken
Crossref

High efficient electrochemical biosensor based on exonuclease-Ⅲ-assisted dual-recycling amplification for ultrasensitive detection of kanamycin

Liang Tian, Jiyuan Zhang, Huiling Fan, Yanci Zhang, Zhanhui Wang, Olayinka Oderinde, Yihong Wang, Jiansheng Cui

Analytical Biochemistry · 2023-02 · 663 · 115028

DOI: 10.1016/j.ab.2022.115028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2023-02. Verfasst von Liang Tian und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental Science and Engineering, Hebei University of Science and Technology, Shijiazhuang, Hebei, 50018, PR China; School of Chemistr…. Hauptthemen laut MEDLINE: Kanamycin, Biosensing Techniques. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hebei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A target-triggered and exonuclease-Ⅲ-assisted strand displacement, dual-recycling amplification reaction-based biosensor was developed for the rapid, ultrasensitive and accurate detection of kanamycin. The robust profiling platform was constructed using high conductive MXene/VS2 for the electrode surface modification and high active CeCu2O4 bimetallic nanoparticles as nanozyme to improve the sensitivity as well as the catalytic signal amplification of the biosensor. Using the dual supplementary recycling of primer DNA and hairpin DNA, the electrochemical platform could accurately detect kanamycin to as low as 0.6 pM from the range of 5 pM to 5 μM. By profiling five other antibiotics, this platform exhibited high specificity, enhanced repeatability and reproducibility. Based on these intrinsic characteristics and by utilizing milk and water samples, the as-designed biosensor offers a remarkable strategy for antibiotic detection due to its favorable analytical accuracy and reliability, thereby demonstrating potential application prospect for various antibiotic biosensing in food quality control, water contamination detection and biological safety analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KanamycinBiosensing TechniquesReproducibility of ResultsElectrochemical TechniquesAnti-Bacterial AgentsDNAWaterLimit of DetectionNitritesTransition Elements

Stichwörter der Autor:innen

CeCu(2)O(4) nanozymeElectrochemical biosensorExonuclease-ⅢKanamycinMXene/VS(2) nanocomposite

Substanzen

KanamycinAnti-Bacterial AgentsDNAWaterMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • School of Environmental Science and Engineering, Hebei University of Science and Technology, Shijiazhuang, Hebei, 50018, PR China; School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, PR…
  • School of Environmental Science and Engineering, Hebei University of Science and Technology, Shijiazhuang, Hebei, 50018, PR China.
  • Hebei Technology Innovation Center for Drinking Water Safety Testing, Chengde, Hebei, 67000, PR China.
  • Department of Chemistry, Faculty of Applied and Natural Sciences, Lead City University, Ibadan, Nigeria.
  • School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, PR China. Electronic address: yihongwang@seu.edu.cn.
  • School of Environmental Science and Engineering, Hebei University of Science and Technology, Shijiazhuang, Hebei, 50018, PR China. Electronic address: cui1603@163.com.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hebei Province

Zitieren

APA

Tian, L., Zhang, J., Fan, H., Zhang, Y., Wang, Z., Oderinde, O., Wang, Y., & Cui, J. (2023). High efficient electrochemical biosensor based on exonuclease-Ⅲ-assisted dual-recycling amplification for ultrasensitive detection of kanamycin. Analytical Biochemistry, 663, 115028. https://doi.org/10.1016/j.ab.2022.115028

Vancouver

Tian L, Zhang J, Fan H, Zhang Y, Wang Z, Oderinde O, et al. High efficient electrochemical biosensor based on exonuclease-Ⅲ-assisted dual-recycling amplification for ultrasensitive detection of kanamycin. Analytical Biochemistry. 2023;663:115028. doi:10.1016/j.ab.2022.115028

BibTeX
@article{Tian2023,
  author = {Tian, Liang and Zhang, Jiyuan and Fan, Huiling and Zhang, Yanci and Wang, Zhanhui and Oderinde, Olayinka and Wang, Yihong and Cui, Jiansheng},
  title = {High efficient electrochemical biosensor based on exonuclease-Ⅲ-assisted dual-recycling amplification for ultrasensitive detection of kanamycin},
  journal = {Analytical Biochemistry},
  year = {2023},
  volume = {663},
  pages = {115028},
  doi = {10.1016/j.ab.2022.115028}
}
Kostenlos starten →