EUVIMEDEUVIMED entdecken
Crossref

Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A

Demet Örenli, Ceren Kaçar Selvi, Funda Öztürk, Pınar Esra Erden, Esma Kılıç

Analytical Biochemistry · 2023-02 · 662 · 115002

DOI: 10.1016/j.ab.2022.115002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2023-02. Verfasst von Demet Örenli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Ankara University, Ankara, Turkey. Hauptthemen laut MEDLINE: Quantum Dots, Ionic Liquids, Metal Nanoparticles. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 72 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical (bio)sensors were developed for bisphenol A (BPA) determination. Screen printed carbon electrode (SPCE) was modified with ionic liquid 1- butyl-3-methylimidazolium tetrafluoroborate (IL), carbon quantum dots (CQD) and gold nanoparticles (AuNP) for the fabrication of the BPA sensor. Electrode surface composition was optimized for the deposition time of AuNP, amount of CQD and percentage of IL using the central composite design (CCD) method. The results of the CCD study indicated that maximum amperometric response was recorded when 9.8 μg CQD, 3% IL and 284 s AuNP deposition time were used in modification. Tyrosinase (Ty) was further modified on the AuNP/CQD-IL/SPCE to fabricate the biosensor. Analytical performance characteristics of the BPA sensor were investigated by differential pulse anodic adsorptive stripping voltammetry and the AuNP/CQD-IL/SPCE sensor exhibited a linear response to BPA in the range of 2.0 × 10-8 - 3.6 × 10-6 M with a detection limit of 1.1 × 10-8 M. Amperometric measurements showed that the linear dynamic range and detection limit of the Ty/AuNP/CQD-IL/SPCE were 2.0 × 10-8 - 4.0 × 10-6 M and 6.2 × 10-9 M, respectively. Analytical performance characteristics such as sensitivity, reproducibility and selectivity were investigated for the presented (bio)sensors. The analytical applicability of the (bio)sensors to the analysis of BPA in mineral water samples was also tested.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quantum DotsIonic LiquidsMetal NanoparticlesCarbonGoldReproducibility of ResultsElectrodesElectrochemical TechniquesBisphenol A Compounds

Stichwörter der Autor:innen

Bisphenol ACarbon quantum dotsElectrochemical biosensorGold nanoparticlesIonic liquid

Substanzen

CarbonGoldIonic Liquidsbisphenol ABisphenol A Compounds

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Ankara University, Ankara, Turkey.
  • Department of Chemistry, Faculty of Science and Arts, Tekirdağ Namık Kemal University, Tekirdağ, Turkey.
  • Department of Chemistry, Polatlı Faculty of Science and Letters, Ankara Haci Bayram Veli University, Ankara, Turkey. Electronic address: erdenpe@gmail.com.

Zitieren

APA

Örenli, D., Kaçar Selvi, C., Öztürk, F., Erden, P. E., & Kılıç, E. (2023). Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A. Analytical Biochemistry, 662, 115002. https://doi.org/10.1016/j.ab.2022.115002

Vancouver

Örenli D, Kaçar Selvi C, Öztürk F, Erden PE, Kılıç E. Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A. Analytical Biochemistry. 2023;662:115002. doi:10.1016/j.ab.2022.115002

BibTeX
@article{renli2023,
  author = {Örenli, Demet and Kaçar Selvi, Ceren and Öztürk, Funda and Erden, Pınar Esra and Kılıç, Esma},
  title = {Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A},
  journal = {Analytical Biochemistry},
  year = {2023},
  volume = {662},
  pages = {115002},
  doi = {10.1016/j.ab.2022.115002}
}
Kostenlos starten →