EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Biomechanical analysis of variable thickness direct-printed aligners for mandibular intrusion

Catherine Weber Clary, Tony Vieira Faria, Yoo Jin Kim, Julie McCray, Patrick Foley, Gabriel Miranda, Ki Beom Kim

Digital and Aligner Orthodontics · 03.11.2026 · 1 (1)

DOI: 10.1007/s44525-026-00017-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital and Aligner Orthodontics, online erschienen am 03.11.2026. Verfasst von Catherine Weber Clary und 6 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This in vitro study evaluated the effect of global and localized thickness modifications in direct-printed aligners (DPAs) on force and moment systems during mandibular intrusion for curve of Spee leveling. A secondary objective was to compare DPA forces and moments against a thermoformed aligner (TFA) control under selected activation conditions.

Methods

A multi-axis sensor was used to measure three-dimensional forces and moments during programmed anterior intrusion. DPAs fabricated with TA-28 resin were tested in six configurations, all with 0.5 mm programmed intrusion and consisting of uniform thicknesses of 0.5 mm and 1.0 mm as well as selectively thickened designs. These groups were compared to a standardized TFA control group with 0.25 mm programmed intrusion.

Results

No statistically significant differences were observed among the DPAs configurations, indicating that localized and global thickness modifications did not significantly influence the generated forces and moments. Across all DPA groups, force magnitudes remained low and consistent. In contrast, TFA produced significantly higher and more variable forces and moments, despite a lower programmed activation. Additionally, lateral incisors consistently exhibited higher intrusive forces than central incisors, suggesting an asymmetric force distribution within the anterior segment.

Conclusion

The biomechanical performance of DPAs is primarily dictated by intrinsic material properties rather than localized thickness, as geometric modifications did not significantly alter force-moment expression. Compared to the TFA control, DPAs provided a more predictable and physiological force system, whereas the thermoforming process resulted in non-physiological loads despite lower activation levels. Clinically, the asymmetrical load distribution observed both in TFA and DPA, suggests that staged sequencing of the anterior teeth is necessary to optimize anchorage and improve predictability of curve of Spee leveling.

Zitieren

APA

Clary, C. W., Faria, T. V., Kim, Y. J., McCray, J., Foley, P., Miranda, G., & Kim, K. B. (2026). Biomechanical analysis of variable thickness direct-printed aligners for mandibular intrusion. Digital and Aligner Orthodontics, 1(1). https://doi.org/10.1007/s44525-026-00017-1

Vancouver

Clary CW, Faria TV, Kim YJ, McCray J, Foley P, Miranda G, et al. Biomechanical analysis of variable thickness direct-printed aligners for mandibular intrusion. Digital and Aligner Orthodontics. 2026;1(1). doi:10.1007/s44525-026-00017-1

BibTeX
@article{Clary2026,
  author = {Clary, Catherine Weber and Faria, Tony Vieira and Kim, Yoo Jin and McCray, Julie and Foley, Patrick and Miranda, Gabriel and Kim, Ki Beom},
  title = {Biomechanical analysis of variable thickness direct-printed aligners for mandibular intrusion},
  journal = {Digital and Aligner Orthodontics},
  year = {2026},
  volume = {1},
  number = {1},
  doi = {10.1007/s44525-026-00017-1}
}
Kostenlos starten →