EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Passive Near-Source Enclosure Device for Reducing Ultrafine Particle Emissions

Alok Kumar Thakur, Rubal Dhiman, Thaseem Thajudeen, Sameer Patel

Aerosol and Air Quality Research · 2026-10 · 26 (10)

DOI: 10.1007/s44408-026-00141-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aerosol and Air Quality Research, online erschienen am 07.07.2026. Verfasst von Alok Kumar Thakur und 3 weiteren Autor:innen. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Prime Minister Research Fellowship, Ministry of Education, Government of India, Science and Engineering Research Board (SERB), Department of Science and Technology, Government of India, Scheme for Promotion of Academic and Research Collaboration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sources such as incense sticks and mosquito coils can lead to high personal exposure to sub-250 nm particles in indoor environments. Although these particles contribute little to total particulate matter mass compared with larger size fractions, increasing evidence suggests that these particles may have greater health relevance due to their high number concentration and large specific surface area. This study evaluates FumeCAP, a passive, low-cost, near-source enclosure device designed to reduce sub-250 nm particle emissions from common household sources, including incense sticks and mosquito coils. Experiments were conducted under control and intervention conditions. Particle number size distributions were measured using a scanning mobility particle sizer. Inhalation exposure was quantified using concentration-time profiles representative of personal exposure scenarios. Aerosol dynamic modeling was applied to estimate reductions in size-resolved emission rates. Regional respiratory tract deposited doses were calculated using particle number, surface area, and mass metrics. The intervention reduced number-based inhalation exposure during 240-minute experiments by 79 ± 5% for incense sticks and 46 ± 10% for mosquito coils. Size-resolved emission rates decreased by 81 ± 21% and 62 ± 15%, respectively, with the largest reductions observed for UFPs. Estimated deposited doses in the head airways, tracheobronchial, and alveolar regions were consistently reduced under intervention conditions. Overall, the results demonstrate that passive, low-cost, near-source control intervention can substantially reduce exposure to sub-250 nm particles from indoor combustion sources without compromising their intended use.

Förderung

  • Prime Minister Research Fellowship, Ministry of Education, Government of India
  • Science and Engineering Research Board (SERB), Department of Science and Technology, Government of India
  • Scheme for Promotion of Academic and Research Collaboration

Zitieren

APA

Thakur, A. K., Dhiman, R., Thajudeen, T., & Patel, S. (2026). A Passive Near-Source Enclosure Device for Reducing Ultrafine Particle Emissions. Aerosol and Air Quality Research, 26(10). https://doi.org/10.1007/s44408-026-00141-2

Vancouver

Thakur AK, Dhiman R, Thajudeen T, Patel S. A Passive Near-Source Enclosure Device for Reducing Ultrafine Particle Emissions. Aerosol and Air Quality Research. 2026;26(10). doi:10.1007/s44408-026-00141-2

BibTeX
@article{Thakur2026,
  author = {Thakur, Alok Kumar and Dhiman, Rubal and Thajudeen, Thaseem and Patel, Sameer},
  title = {A Passive Near-Source Enclosure Device for Reducing Ultrafine Particle Emissions},
  journal = {Aerosol and Air Quality Research},
  year = {2026},
  volume = {26},
  number = {10},
  doi = {10.1007/s44408-026-00141-2}
}