Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review

Laura Asensio-Jurado, Marc Argilés, Xavier Molinero, Bernat Sunyer-Grau, Dennis M Levi

Ophthalmic and Physiological Optics · 14.11.2026

DOI: 10.1007/s44402-026-00230-0 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 14.11.2026. Verfasst von Laura Asensio-Jurado und 4 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain. laura.as…. Die Arbeit nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Stereoacuity is increasingly used as an outcome measure in amblyopia and strabismus research, yet the way unmeasurable (‘nil’) values are handled, and the way stereoacuity is expressed vary across studies in ways that compromise the comparability of published findings. This review quantifies that variability and proposes a minimum reporting standard.

Methods

A systematic review was conducted following PRISMA guidelines (OSF: 10.17605/OSF.IO/TY7FG), including studies published from 2010 onward that reported stereoacuity as an outcome in amblyopia or strabismus. For each study, the notation used to express stereoacuity was coded, whether the baseline prevalence of nil was reported and how nil observations were handled analytically. Reporting completeness was scored from 0 to 3 and its changes over time were assessed.

Results

Across 79 studies (2010–2026; 7,466 participants), the baseline prevalence of nil could not be determined in 54%. Among studies imputing a fixed value to nil, ten values were used, from 400 to 100,000 arcsec (a 250-fold span, eight octaves). Notation varied across two logarithmic bases and untransformed arcsec, and scale convention was strongly associated with nil-handling strategy ( χ ² = 24.46, p < 0.001), defining two methodological ecosystems that yield non-comparable results. Reporting completeness declined over the review period (Spearman’s ρ = −0.37, p < 0.001). In simulations, these inconsistencies produced up to an 8.4-fold difference in apparent effect size for an identical clinical change.

Conclusions

The expression and reporting of stereoacuity are highly heterogeneous, and this introduces an undetectable source of variability in evidence synthesis. A five-item minimum reporting standard is proposed covering the test, and its disparity range, the prevalence and definition of nil, its analytical treatment and the notation used, to make these choices explicit for authors, reviewers and editors.

Schlagwörter

Stichwörter der Autor:innen

AmblyopiaCensored dataDepth perceptionReporting standardsStereoacuityStrabismus

Autor:innen und Institutionen

  • Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain. laura.asensio@upc.edu.
  • Hospital Universitari Mútua Terrassa, Terrassa, Spain. laura.asensio@upc.edu.
  • Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain.
  • Algorithmics, Bioinformatics, Complexity and Formal Methods (ALBCOM Research Group), Departament de Matemàtiques (DMAT), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain.
  • Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley, California, USA.

Zitieren

APA

Asensio-Jurado, L., Argilés, M., Molinero, X., Sunyer-Grau, B., & Levi, D. M. (2026). Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review. Ophthalmic and Physiological Optics. https://doi.org/10.1007/s44402-026-00230-0

Vancouver

Asensio-Jurado L, Argilés M, Molinero X, Sunyer-Grau B, Levi DM. Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review. Ophthalmic and Physiological Optics. 2026. doi:10.1007/s44402-026-00230-0

BibTeX
@article{AsensioJurado2026,
  author = {Asensio-Jurado, Laura and Argilés, Marc and Molinero, Xavier and Sunyer-Grau, Bernat and Levi, Dennis M},
  title = {Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review},
  journal = {Ophthalmic and Physiological Optics},
  year = {2026},
  doi = {10.1007/s44402-026-00230-0}
}
Kostenlos starten →