Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents
Ophthalmic and Physiological Optics · 2026
DOI: 10.1007/s44402-026-00148-7 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Ophthalmic and Physiological Optics, 2026. Verfasst von Wenjun Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Tongren Eye Centre, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Key Laboratory of Intelligent Diagnosis Technology …. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Myopia, Sleep Stages. Die Arbeit nennt 68 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Youth Vision Public Welfare Project, Beijing Natural Science Foundation.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
PURPOSE: To validate a wrist-worn multimodal wearable system for synchronised monitoring of multispectral light exposure, activity phenotypes and five-stage sleep architecture in children and adolescents in a structured 24-h pilot validation protocol. METHODS: A wrist-mounted multimodal wearable system was developed, integrating a 9-channel multispectral light sensor (350-1000 nm), a 9-axis inertial measurement unit (IMU) and a photoplethysmography (PPG) sensor for synchronised acquisition of environmental light, body movement and cardiovascular signals. Twelve healthy children and adolescents (mean age: 10.04 ± 3.26 years; range: 6-15 years) underwent a 24-h pilot validation protocol. Long short-term memory (LSTM) networks were developed for activity recognition and a Stacking ensemble framework combined with cost-sensitive learning was implemented for five-stage sleep classification, i.e., wake (W), non-rapid eye movement stage 1 (N1), non-rapid eye movement stage 2 (N2), non-rapid eye movement stage 3 (N3) and rapid eye movement (REM). RESULTS: Under the three lighting conditions tested, the device captured distinct spectral irradiance profiles: outdoor natural light (1.8 W m-2 nm-1; broad-spectrum 350-1000 nm), indoor natural light (0.30 W m-2 nm-1) and artificial illumination (0.07 W m-2 nm-1; peak at 545-600 nm). The LSTM-based model achieved 86.33% overall accuracy for five-activity classification, with 92.4% for writing and 91.5% for walking. The Stacking ensemble sleep classifier attained 83.41% overall accuracy; cost-sensitive learning improved N3 and REM detection by 15.8% and 8.9%, respectively. Incorporation of PPG signals enhanced activity recognition accuracy by 3.62%. CONCLUSIONS: This multimodal platform enabled objective, high-resolution quantification of paediatric light exposure, behaviour and sleep architecture in a structured pilot validation setting, supporting individualised assessment of modifiable myopia-related factors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Tongren Eye Centre, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Key Laboratory of Intelligent Diagnosis Technology and Equipment for Optic Nerve-Related Eye Diseases, Capital Medical Un…
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
- Beijing An Zhen Hospital, Capital Medical University, The Key Laboratory of Remodelling Cardiovascular Diseases, Ministry of Education, Beijing, China.
- Collaborative Innovation Center for Cardiovascular Disorders, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing, China.
Förderung
- National Natural Science Foundation of China
- Youth Vision Public Welfare Project
- Beijing Natural Science Foundation
Zitieren
APA
Xu, W., Chen, J., Zhang, Z., Wang, J., Li, S., Wang, N., Gao, S., & Kang, M. (2026). Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents. Ophthalmic and Physiological Optics. https://doi.org/10.1007/s44402-026-00148-7
Vancouver
Xu W, Chen J, Zhang Z, Wang J, Li S, Wang N, et al. Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents. Ophthalmic and Physiological Optics. 2026. doi:10.1007/s44402-026-00148-7
BibTeX
@article{Xu2026,
author = {Xu, Wenjun and Chen, Junliang and Zhang, Zihang and Wang, Jiaqi and Li, Shiming and Wang, Ningli and Gao, Shuo and Kang, Mengtian},
title = {Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents},
journal = {Ophthalmic and Physiological Optics},
year = {2026},
doi = {10.1007/s44402-026-00148-7}
}
EUVIMED