Development and validation of an LC–MS/MS method for the quantification of Lurasidone in rabbit plasma
Discover Chemistry · 27.07.2026 · 3 (1)
DOI: 10.1007/s44371-026-00866-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Discover Chemistry, online erschienen am 27.07.2026. Verfasst von Bipasha Behera und 2 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Liquid chromatographic mass spectrometry was used to develop the current bioanalytical method, which was newly established to determine the quantity of Lurasidone in plasma estimation of rabbits.
Methods
Chromatographic separation was carried out on an Atlantis HILIC Silica C18 column (150 × 4.6 mm, 5 μm, Waters, USA), analytical column with a mobile phase consisting of acetonitrile: 0.1% formic acid, 90:10 ratio. The production mass value of Lurasidone was found m/z + 493.25 (parent) →266.3 (product) and m/z + 326.6 (parent)→245.31 (product) for clozapine.
Results
Extraction of the drug from the spiked plasma was accomplished using the liquid-liquid extraction technique. As evidenced by extraction recovery (98.86%) (Interference = 0), matrix and analyte selectivity were high. A linear calibration curve was seen from 0.5 to 5000 ng/ml, and all kinds of stability study results (99.87%) were good. Accuracy ranged from 96.21 to 98.42%, with precision < 2% at all quality control levels. In pharmacokinetic analysis, Lurasidone has an AUC0−t of 122 ± 7.52 h.ng/ml. The half-life of elimination (t1/2) is 7.46 ± 1.66 h.
Conclusion
The method, considered a novel and validated bioanalytical approach based on experimental findings, was utilized for pharmacokinetic studies of commercial formulations using rabbit plasma samples.
Zitieren
APA
Behera, B., Mishra, U. S., & Sahoo, S. K. (2026). Development and validation of an LC–MS/MS method for the quantification of Lurasidone in rabbit plasma. Discover Chemistry, 3(1). https://doi.org/10.1007/s44371-026-00866-4
Vancouver
Behera B, Mishra US, Sahoo SK. Development and validation of an LC–MS/MS method for the quantification of Lurasidone in rabbit plasma. Discover Chemistry. 2026;3(1). doi:10.1007/s44371-026-00866-4
BibTeX
@article{Behera2026,
author = {Behera, Bipasha and Mishra, Uma Shankar and Sahoo, Sudhir Kumar},
title = {Development and validation of an LC–MS/MS method for the quantification of Lurasidone in rabbit plasma},
journal = {Discover Chemistry},
year = {2026},
volume = {3},
number = {1},
doi = {10.1007/s44371-026-00866-4}
}
EUVIMED