EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery

Sayed Gaber Ali, Hatem Alatroush, Emad Eldeen Omar, Mamdouh Kotb, Mohamed Abouel-wafa

The Egyptian Journal of Critical Care Medicine · 2026-12 · 13 (1)

DOI: 10.1007/s44349-026-00041-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Egyptian Journal of Critical Care Medicine, online erschienen am 02.04.2026. Verfasst von Sayed Gaber Ali und 4 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality.

Aim

This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients.

Methods

A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed.

Results

The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods ( r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS.

Conclusion

Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.

Zitieren

APA

Ali, S. G., Alatroush, H., Omar, E. E., Kotb, M., & Abouel-wafa, M. (2026). Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery. The Egyptian Journal of Critical Care Medicine, 13(1). https://doi.org/10.1007/s44349-026-00041-9

Vancouver

Ali SG, Alatroush H, Omar EE, Kotb M, Abouel-wafa M. Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery. The Egyptian Journal of Critical Care Medicine. 2026;13(1). doi:10.1007/s44349-026-00041-9

BibTeX
@article{Ali2026,
  author = {Ali, Sayed Gaber and Alatroush, Hatem and Omar, Emad Eldeen and Kotb, Mamdouh and Abouel-wafa, Mohamed},
  title = {Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery},
  journal = {The Egyptian Journal of Critical Care Medicine},
  year = {2026},
  volume = {13},
  number = {1},
  doi = {10.1007/s44349-026-00041-9}
}
Kostenlos starten →