RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study
The Egyptian Journal of Critical Care Medicine · 2026-12 · 13 (1)
DOI: 10.1007/s44349-025-00040-2 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift The Egyptian Journal of Critical Care Medicine, online erschienen am 02.03.2026. Verfasst von Soliman Belal Soliman und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Sepsis
Abstract (Originalsprache)
Introduction
A prospective cohort investigation was undertaken between November 2022 and April 2024, encompassing 50 patients with septic shock. The study evaluated fluid responsiveness through the assessment of right ventricular-arterial coupling (RVAC), quantified using the ratios TAPSE/PASP and TAPSE*PVAT, with left ventricular outflow tract velocity–time integral (LVOT-VTI) serving as the comparative parameter. Aim of the study Investigation of the association between non-invasive right ventricular-arterial coupling parameters and LVOT-VTI measurements post-fluid administration for predicting volume responsiveness in septic shock patients.
Methods
Each participant underwent fluid challenge protocols accompanied by standard echocardiographic evaluations. Right ventricular-arterial coupling parameters, including TAPSE/PASP and TAPSE*PVAT ratios, were documented to determine volume responsiveness. Patient stratification into responsive and non-responsive cohorts was established based on left ventricular outflow tract velocity–time integral (LVOT-VTI) alterations, with increases of ≥ 12% defining the responder category.
Results
The mean TAPSE/PASP was (0.63 ± 0.23 vs 0.42 ± 0.17, P = 0.002, Cut-off: 0.47, AUC 0.764, 95% CI:]0.622–0.902[ specificity 78.1% and sensitivity 72.2%) in the responder vs the non-responder group respectively, The mean TAPSE*PVAT was (227.51 ± 45.67 vs 178.52 ± 52.37, P = 0.003, Cut-off: 214.5, AUC 0.722, 95% CI:]0.618–0.896[specificity 71.3% and sensitivity 75%) in the responder vs the non-responder group respectively.
Conclusion
RVAC, expressed as TAPSE/PASP, demonstrated predictive value for fluid responsiveness in septic shock. TAPSE × PVAT may serve as an alternative non-invasive parameter.
Zitieren
APA
Soliman, S. B., Mahmoud, M. M., Fakher, M. A., Nour, M. K., & Nassar, Y. S. (2026). RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study. The Egyptian Journal of Critical Care Medicine, 13(1). https://doi.org/10.1007/s44349-025-00040-2
Vancouver
Soliman SB, Mahmoud MM, Fakher MA, Nour MK, Nassar YS. RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study. The Egyptian Journal of Critical Care Medicine. 2026;13(1). doi:10.1007/s44349-025-00040-2
BibTeX
@article{Soliman2026,
author = {Soliman, Soliman Belal and Mahmoud, Mahmoud Mostafa and Fakher, Mohamed Amin and Nour, Mahmoud Khaled and Nassar, Yasser Sadek},
title = {RVAC as TAPSE/PASP and TAPSE*PVAT as a novel static parameter to assess fluid responsiveness in septic shock patients, a prospective cohort study},
journal = {The Egyptian Journal of Critical Care Medicine},
year = {2026},
volume = {13},
number = {1},
doi = {10.1007/s44349-025-00040-2}
}
EUVIMED