Compliance to ventilator care bundles and its association with ventilator-associated pneumonia
Einhaltung von Ventilator-Care-Bundles und Zusammenhang mit ventilatorassoziierter Pneumonie
Anesthesiology and Perioperative Science · 17.04.2024 · 2 (2)
DOI: 10.1007/s44254-024-00059-1 ↗Auf einen Blick
In einer retrospektiven Kohortenstudie war die Einhaltung des IHI-Bundles in der MIMIC-IV-Kohorte gering. Mehr Bundle-Interventionen waren mit weniger VAP assoziiert.
Fragestellung
Wie gut war die Compliance mit dem IHI-Ventilator-Bundle in der MIMIC-IV-Kohorte, und wie hing sie mit der VAP-Inzidenz zusammen?
Methode
Retrospektive Kohortenstudie der MIMIC-IV-Datenbank bei Patient:innen mit > 48 h invasiver Beatmung; VAP per ICD-9/ICD-10; Analyse univariat und multivariat.
Ergebnisse
8.270 Patient:innen; 1.328 (16,1 %) mit VAP. Vollständige Compliance: 25 (0,3 %). Pro zusätzlicher Intervention niedrigere VAP-Inzidenz (OR 0,906; 95 %-KI 0,847–0,969).
Schlussfolgerung der Autor:innen
Die Nutzung des IHI-Bundles war mit einer niedrigeren VAP-Inzidenz verbunden, die Compliance war jedoch schlecht. Bessere Compliance könnte VAP-Raten senken.
Kernaussagen
- VAP bei 1.328 von 8.270 Patient:innen
- Vollständige Bundle-Compliance nur bei 25 Patient:innen
- Sedierung und HME-Filter waren mit weniger VAP assoziiert
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Anesthesiology and Perioperative Science, online erschienen am 17.04.2024. Verfasst von Yun Hao Leong und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Pneumonieprophylaxe
Abstract (Originalsprache)
Purpose
Ventilator care bundles are effective in the prevention of ventilator-associated pneumonia (VAP). However, the compliance of these bundles in intensive care units (ICUs) remains poorly studied. This study investigates the Medical Information Mart for Intensive Care (MIMIC)-IV cohort’s compliance with the Institute for Healthcare Improvement (IHI) bundle and its resulting association with VAP incidence.
Methods
This is a retrospective cohort study of the MIMIC-IV database. Patients with > 48 h of invasive mechanical ventilation (IMV) were included. Diagnosis of VAP was identified with the International Classification of Diseases (ICD)-9 and ICD-10 codes. Compliance rates to the IHI bundle were extracted. The association of the IHI bundle and its individual interventions with VAP incidence was analyzed with univariate and multivariate analysis.
Results
8270 patients were included, of which 1328 (16.1%) had VAP. 25 patients (0.3%) had full compliance to the IHI bundle. 137 patients (1.7%) received no interventions from the bundle. Gastroprophylaxis had the lowest (2.1%) while head elevation had the highest (89.3%) compliance rates. In patients receiving the IHI bundle, each additional intervention was associated with lower VAP incidence (OR [odds ratio] = 0.906, 95% CI [confidence interval] 0.847–0.969). Appropriate sedation levels (OR = 0.765, 95% CI 0.661–0.885) and the use of heat and moisture exchanger (HME) filters (OR = 0.862, 95% CI 0.745–0.998) were individually associated with reduced VAP incidence, while active humidification was individually associated with increased VAP incidence (OR = 1.139, 95% CI 1.001–1.296).
Conclusion
The use of the IHI bundle was associated with a lower incidence of VAP, but compliance with the bundle was poor. Appropriate sedation and HME filters were individually associated with reduced VAP incidence. Better compliance with the IHI bundle may reduce VAP rates in mechanically ventilated patients. Graphical Abstract
Zitieren
APA
Leong, Y. H., Khoo, Y. L., Abdullah, H. R., & Ke, Y. (2024). Compliance to ventilator care bundles and its association with ventilator-associated pneumonia. Anesthesiology and Perioperative Science, 2(2). https://doi.org/10.1007/s44254-024-00059-1
Vancouver
Leong YH, Khoo YL, Abdullah HR, Ke Y. Compliance to ventilator care bundles and its association with ventilator-associated pneumonia. Anesthesiology and Perioperative Science. 2024;2(2). doi:10.1007/s44254-024-00059-1
BibTeX
@article{Leong2024,
author = {Leong, Yun Hao and Khoo, You Liang and Abdullah, Hairil Rizal and Ke, Yuhe},
title = {Compliance to ventilator care bundles and its association with ventilator-associated pneumonia},
journal = {Anesthesiology and Perioperative Science},
year = {2024},
volume = {2},
number = {2},
doi = {10.1007/s44254-024-00059-1}
}
EUVIMED