Analysis of trace gold in sub-microliter samples by surface-enhanced laser-induced breakdown spectroscopy using porous silicon with a single laser shot
Analytical Sciences · 2026-10 · 42 (10) · 941-951
DOI: 10.1007/s44211-026-00951-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Sciences, online erschienen am 30.07.2026. Verfasst von Yui Sugita und 4 weiteren Autor:innen. Beteiligte Einrichtung: Field of Chemistry, Department of Engineering, Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo, 671-2280, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Industry-Academia Collaborative Research Grant from Himeji City.
Abstract (Originalsprache)
Surface-enhanced laser-induced breakdown spectroscopy (SELIBS) using porous silicon (Si) is an attractive technique for liquid analysis in terms of requiring only microvolume samples, simple pretreatment, and a low plasma generation threshold. These features make SELIBS particularly suitable for industrial process monitoring, such as wet metal recovery processes. In our previous studies, we have analyzed sample solutions with volumes of approximately 10 µL by accumulating multiple spectra measured over the spread area of the sample. Reducing the volume of sample solutions and enabling rapid analysis remain important challenges for practical applications. In this study, we demonstrate single-shot analysis of trace gold (Au) in sub-microliter solution samples by SELIBS using porous Si, representing a step toward practical use. The emission line of Au was successfully observed using only 0.5 µL of sample and a single laser shot with an energy of 2.0 mJ. A calibration curve for Au was built using the Au intensity normalized by the Si intensity in the Au concentration range of 0.5-5.0 ppm (mg/L). From this calibration curve, a coefficient of determination of 0.997 was obtained. The limit of detection was estimated to be 0.48 ppm based on the Au intensity. The relative errors of predicted Au concentrations in additionally analyzed samples using the Au/Si calibration curve were approximately 10%. The proposed method has a potential for in-situ monitoring of wet metal recovery processes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Field of Chemistry, Department of Engineering, Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo, 671-2280, Japan.
- Field of Chemistry, Department of Engineering, Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo, 671-2280, Japan. matsumoto.ayumu@eng.u-hyogo.ac.jp.
Förderung
- Japan Society for the Promotion of Science
- Industry-Academia Collaborative Research Grant from Himeji City
Zitieren
APA
Sugita, Y., Matsumoto, A., Torigoe, H., Kuroda, K., & Yae, S. (2026). Analysis of trace gold in sub-microliter samples by surface-enhanced laser-induced breakdown spectroscopy using porous silicon with a single laser shot. Analytical Sciences, 42(10), 941-951. https://doi.org/10.1007/s44211-026-00951-9
Vancouver
Sugita Y, Matsumoto A, Torigoe H, Kuroda K, Yae S. Analysis of trace gold in sub-microliter samples by surface-enhanced laser-induced breakdown spectroscopy using porous silicon with a single laser shot. Analytical Sciences. 2026;42(10):941-951. doi:10.1007/s44211-026-00951-9
BibTeX
@article{Sugita2026,
author = {Sugita, Yui and Matsumoto, Ayumu and Torigoe, Hiroto and Kuroda, Kiichi and Yae, Shinji},
title = {Analysis of trace gold in sub-microliter samples by surface-enhanced laser-induced breakdown spectroscopy using porous silicon with a single laser shot},
journal = {Analytical Sciences},
year = {2026},
volume = {42},
number = {10},
pages = {941--951},
doi = {10.1007/s44211-026-00951-9}
}
EUVIMED