EUVIMEDEUVIMED entdecken
Crossref

Accurate evaluation of diffusion coefficient for electroactive analytes in human serum samples using nitrogen-terminated sputtered carbon film electrode

Saki Ohta, Tomonori Ozawa, Shunsuke Shiba, Tatsuhiko Yajima, Tomoyuki Kamata, Dai Kato, Osamu Niwa

Analytical Sciences · 2025

DOI: 10.1007/s44211-025-00718-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Sciences, 2025. Verfasst von Saki Ohta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0…. Hauptthemen laut MEDLINE: Carbon, Nitrogen, Electrochemical Techniques, Acetaminophen. Die Arbeit nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We have developed an N-terminated carbon film electrode that allows accurate determination of the diffusion coefficient of electroactive molecules dissolved in a highly concentrated serum protein solution. The carbon film electrode was formed by the unbalanced magnetron sputtering (UBM) method. Then, nitrogen functional groups were introduced by employing NH3 or H2O plasma treatment. Cyclic voltammetry measurements with ferricyanide ion ([Fe(CN)6]3-) showed that the N-terminated carbon film electrode exhibited great anti-fouling property against simulated serum proteins (50 mg/mL human serum albumin and 15 mg/mL γ-globulin dissolved in 1 M KCl solution). In contrast, glassy carbon, H2O plasma-treated, and especially untreated carbon film electrodes were subject to severe electrode fouling, making it difficult to electrochemically determine the diffusion coefficient of the [Fe(CN)6]3- ion. The control experiment using less adsorptive ethylene glycol as a viscosity modifier showed that the increase in viscosity is a main factor of the decrease in diffusion coefficient for nitrogen plasma treated electrode, which is not significantly affected by the possible interaction between [Fe(CN)6]3- ions and serum proteins. Finally, we applied the electrode for the electrochemical analysis of acetaminophen dissolved in phosphate buffer (0.1 M, pH = 7.0), which suggests that NH3 plasma-treated carbon film exhibits the lowest ΔE increase when we compare ΔE with and without proteins and also a more stable peak current in continuous voltametric measurements compared with other carbon electrodes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarbonNitrogenElectrochemical TechniquesAcetaminophenBlood Chemical AnalysisHumansElectrodesDiffusion

Stichwörter der Autor:innen

Acetaminophen (APAP)Carbon film electrodeDiffusion coefficientNH3 plasma-treatment

Substanzen

CarbonNitrogenAcetaminophen

Autor:innen und Institutionen

  • Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan.
  • Asahi FR R&D Co., Ltd., Kayane Tsukinoiri, Shirakawa, Fukushima, 961-0004, Japan.
  • Advanced Materials Research Laboratory, NiSiNa Materials Co. Ltd., 2-6-20-3, Kitagata, Kita-ku, Okayama, Okayama, 700-0803, Japan.
  • Advanced Science Research Laboratory, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan.
  • Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8566, Japan.
  • Department of Life Science and Green Chemistry, Graduate School of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama, 369-0293, Japan. niwa@sit.ac.jp.

Zitieren

APA

Ohta, S., Ozawa, T., Shiba, S., Yajima, T., Kamata, T., Kato, D., & Niwa, O. (2025). Accurate evaluation of diffusion coefficient for electroactive analytes in human serum samples using nitrogen-terminated sputtered carbon film electrode. Analytical Sciences. https://doi.org/10.1007/s44211-025-00718-8

Vancouver

Ohta S, Ozawa T, Shiba S, Yajima T, Kamata T, Kato D, et al. Accurate evaluation of diffusion coefficient for electroactive analytes in human serum samples using nitrogen-terminated sputtered carbon film electrode. Analytical Sciences. 2025. doi:10.1007/s44211-025-00718-8

BibTeX
@article{Ohta2025,
  author = {Ohta, Saki and Ozawa, Tomonori and Shiba, Shunsuke and Yajima, Tatsuhiko and Kamata, Tomoyuki and Kato, Dai and Niwa, Osamu},
  title = {Accurate evaluation of diffusion coefficient for electroactive analytes in human serum samples using nitrogen-terminated sputtered carbon film electrode},
  journal = {Analytical Sciences},
  year = {2025},
  doi = {10.1007/s44211-025-00718-8}
}
Kostenlos starten →