EUVIMEDEUVIMED entdecken
Crossref

Computational quality-by-design strategy to validate high-performance liquid chromatography method for the estimation of meloxicam in bulk dosage forms and milk samples

Vaskuri G S Sainaga Jyothi, Harithasree Veerabomma, Chantibabu Katta, Jitender Madan

Analytical Sciences · 2024

DOI: 10.1007/s44211-023-00448-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Sciences, 2024. Verfasst von Vaskuri G S Sainaga Jyothi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Milk, Mastitis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bovine clinical mastitis has significant repercussions for farmers across the globe. Meloxicam, a COX-2 inhibitor, attenuates mastitis symptoms and is also approved for veterinary use. An RP-HPLC (Reverse Phase-High Performance Liquid Chromatography) method development and validation is essential in the pharmaceutical industry to assess API (Active Pharmaceutical Ingredient) quantity present in the pharmaceutical dosage forms. RP-HPLC method of meloxicam was developed and optimized with the aid of QbD (Quality by Design) using Box-Behnken design (BBD). The pH of the aqueous mobile phase, acetonitrile (ACN) percentage, and column temperature were chosen as influence variables, and retention time (RT) and tailing factor (Tf) were selected as response variables. The optimum experimental conditions were selected as pH ~ 3 of the aqueous mobile phase, 65% v/v ACN, and 30˚C as column temperature. The drug was eluted at 6.02 min RT with 1.18 as Tf. The method was subjected to validation for accuracy, linearity, precision, range, sensitivity, and robustness and was found to comply with ICH Q2 (R1) guidelines. The in vitro bioequivalent studies were performed in hydrochloric acid, pH ~ 1.2; acetate buffer, pH ~ 4.5; and phosphate buffer, pH ~ 6.8 for two veterinary brands of meloxicam tablets, and their release profiles were compared by mathematical models. Both the brands, brand 1 and 2 exhibited significant (Unpaired t-test, P 50) in terms of release of meloxicam except at pH 6.8 (f2 = 47.01). The in vitro release of meloxicam followed Peppas kinetics except for brand 2 at pH 6.8, where it followed the Higuchi model. Moreover, the recovery of meloxicam extracted with ACN in the milk sample was estimated to be 99.67 ± 0.58% significantly (Unpaired t-test, P < 0.05) higher than 90.34 ± 6.77% extracted with methanol. In conclusion, the optimized and validated RP-HPLC method of meloxicam may further be used for the analysis of drug content in pharmaceutical dosage forms in addition to biological fluids.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MilkMastitisAnimalsCattleFemaleHumansMeloxicamChromatography, High Pressure LiquidReproducibility of ResultsTablets

Stichwörter der Autor:innen

BBDRP-HPLC methodRelease kineticsSimilarity factorValidation

Substanzen

MeloxicamTablets

Autor:innen und Institutionen

  • Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India.
  • Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India. jitenderpharmacy@gmail.com.

Zitieren

APA

Jyothi, V. G. S. S., Veerabomma, H., Katta, C., & Madan, J. (2024). Computational quality-by-design strategy to validate high-performance liquid chromatography method for the estimation of meloxicam in bulk dosage forms and milk samples. Analytical Sciences. https://doi.org/10.1007/s44211-023-00448-9

Vancouver

Jyothi VGSS, Veerabomma H, Katta C, Madan J. Computational quality-by-design strategy to validate high-performance liquid chromatography method for the estimation of meloxicam in bulk dosage forms and milk samples. Analytical Sciences. 2024. doi:10.1007/s44211-023-00448-9

BibTeX
@article{Jyothi2024,
  author = {Jyothi, Vaskuri G S Sainaga and Veerabomma, Harithasree and Katta, Chantibabu and Madan, Jitender},
  title = {Computational quality-by-design strategy to validate high-performance liquid chromatography method for the estimation of meloxicam in bulk dosage forms and milk samples},
  journal = {Analytical Sciences},
  year = {2024},
  doi = {10.1007/s44211-023-00448-9}
}
Kostenlos starten →