A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring
Discover Artificial Intelligence · 30.10.2026 · 6 (1)
DOI: 10.1007/s44163-026-02679-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Discover Artificial Intelligence, online erschienen am 30.10.2026. Verfasst von Mohamed Mostafa Abdulali. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The Internet of Medical Things requires physiological monitoring systems that balance temporal signal dynamics, relational structure, and computational efficiency. This study presents a lightweight hybrid LSTM–GNN framework for binary ECG screening, integrating explicit graph message passing, temporal modelling, and an ECG-derived proxy-context node. The framework was evaluated on 47 MIT-BIH records using strict record-wise splitting, preprocessing designed to avoid information leakage, and a fixed 0.50 decision threshold across five random seeds. In addition, an external cross-database evaluation was conducted on the INCART database without fine-tuning or threshold tuning, using a harmonized binary label mapping. On MIT-BIH, the Full Hybrid condition achieved the highest mean Accuracy (0.8991 ± 0.0363) and F1-score (0.8121 ± 0.0573), together with the lowest false-alarm rate (0.1129 ± 0.0523) among the evaluated conditions. On the external INCART database, the Full Hybrid condition achieved a mean Accuracy of 0.8801 ± 0.0151 and ROC-AUC of 0.9065 ± 0.0227 under the fixed external-test protocol. The ablation analysis indicated measurable contributions from the combined representations, while the context-permutation analysis showed that the proxy context should not be interpreted as an independent modality. In addition, software-level runtime profiling using ONNX Runtime demonstrated software-level portability characteristics and runtime efficiency on a standard CPU environment, with 8066 parameters, an approximately 36.1-kB model file, and a median CPU latency of 0.076 ms. The reported variability summarizes performance variation across five random seeds reflecting training stability, and should not be interpreted as patient-level inferential confidence intervals. These findings support reproducible, lightweight cross-database evaluation under the specified harmonization protocol, while limiting the claims to software-level computational feasibility rather than physical edge deployment, independent multimodal sensing, autonomous adaptive behavior, or established clinical utility.
Zitieren
APA
Abdulali, M. M. (2026). A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring. Discover Artificial Intelligence, 6(1). https://doi.org/10.1007/s44163-026-02679-x
Vancouver
Abdulali MM. A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring. Discover Artificial Intelligence. 2026;6(1). doi:10.1007/s44163-026-02679-x
BibTeX
@article{Abdulali2026,
author = {Abdulali, Mohamed Mostafa},
title = {A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring},
journal = {Discover Artificial Intelligence},
year = {2026},
volume = {6},
number = {1},
doi = {10.1007/s44163-026-02679-x}
}
EUVIMED