EUVIMEDEUVIMED entdecken
Crossref

TPE-based cationic AIEgen with large stokes shift enables detection of blood anti-coagulator heparin with high selectivity

Sandhya Vilas Yadav, Sandip Kumar Deb, Partha Sarathi Addy, Padma Nilaya Jonnalgadda, Goutam Chakraborty

Photochemical & Photobiological Sciences · 2026

DOI: 10.1007/s43630-026-00867-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photochemical & Photobiological Sciences, 2026. Verfasst von Sandhya Vilas Yadav und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai, 400085, India. Hauptthemen laut MEDLINE: Heparin, Anticoagulants, Fluorescent Dyes, Ethylenes. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Board of Radiation and Nuclear Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this present study, a thiazolium based tetraphenyl ethylene derivative (TPET) was developed for the sensitive and selective detection of heparin (Hp), exploiting the aggregation-induced emission (AIE) feature of TPE. The probe, TPET remains weakly emissive in its dispersed monomeric form but exhibits a pronounced fluorescence "turn-on" response upon interaction with Hp. The probe, TPET due to its inherent cationic nature, experiences a strong electrostatic interaction at the vicinity of polyanionic Hp, which eventually helps TPE derivative to form aggregated species, leading to fluorescence light up response via aggregation-induced emission (AIE). This strategy allows for reliable detection of Hp down to 20.2 nM in aqueous solution. Furthermore, ruggedness of the dye-Hp complex across a broad pH range, showcasing the excellent stability and environmental robustness of the TPE-based system. Importantly, the probe demonstrates excellent preferential response towards heparin compared to other glucosamines and bio-analytes, encouraging its utilization for Hp detection even in complex biomedia. The system achieved a low limit of detection (LOD) of 614.9 nM and 78.4 nM in 25% artificial urine and 0.5% human serum, respectively. Additionally, the dye-Hp complex can also be applied for the detection of Hp antidote, protamine (Pr) as low as 0.15 μM. Overall, this work demonstrates a promising, facile, and non-invasive method for Hp detection, which can be extended to biomedical and clinical diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeparinAnticoagulantsFluorescent DyesEthylenesThiazolesSpectrometry, FluorescenceHumansCationsFluorescent Chemosensor CompoundsHydrogen-Ion ConcentrationLimit of Detection

Stichwörter der Autor:innen

Aggregation-induced emission (AIE)Electrostatic interactionHeparin (Hp)Protamine (Pr)Tetraphenyl ethylene (TPE)

Substanzen

HeparinCationsAnticoagulantsFluorescent DyesEthylenesFluorescent Chemosensor CompoundsThiazoles

Autor:innen und Institutionen

  • Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.
  • K. J. Somaiya College of Science and Commerce, Mumbai, 400077, India.
  • Department of Chemistry, Birla Institute of Technology and Science, Pilani Campus, Pilani, Rajasthan, 333031, India.
  • Homi Bhabha National Institute, Anushaktinagar, Mumbai, 400094, India.
  • Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai, 400085, India. gchak@barc.gov.in.
  • Homi Bhabha National Institute, Anushaktinagar, Mumbai, 400094, India. gchak@barc.gov.in.

Förderung

  • Board of Radiation and Nuclear Science

Zitieren

APA

Yadav, S. V., Deb, S. K., Addy, P. S., Jonnalgadda, P. N., & Chakraborty, G. (2026). TPE-based cationic AIEgen with large stokes shift enables detection of blood anti-coagulator heparin with high selectivity. Photochemical & Photobiological Sciences. https://doi.org/10.1007/s43630-026-00867-3

Vancouver

Yadav SV, Deb SK, Addy PS, Jonnalgadda PN, Chakraborty G. TPE-based cationic AIEgen with large stokes shift enables detection of blood anti-coagulator heparin with high selectivity. Photochemical & Photobiological Sciences. 2026. doi:10.1007/s43630-026-00867-3

BibTeX
@article{Yadav2026,
  author = {Yadav, Sandhya Vilas and Deb, Sandip Kumar and Addy, Partha Sarathi and Jonnalgadda, Padma Nilaya and Chakraborty, Goutam},
  title = {TPE-based cationic AIEgen with large stokes shift enables detection of blood anti-coagulator heparin with high selectivity},
  journal = {Photochemical & Photobiological Sciences},
  year = {2026},
  doi = {10.1007/s43630-026-00867-3}
}
Kostenlos starten →