Fachartikel in der Zeitschrift Therapeutic Innovation & Regulatory Science, online erschienen am 10.08.2026. Verfasst von Kai Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Eli Lilly and Company, Indianapolis, IN, USA. Hauptthemen laut MEDLINE: Maximum Tolerated Dose. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Cancer Institute.
Abstract (Originalsprache)
The US Food and Drug Administration (FDA) launched Project Optimus and issued guidance to reform dose-finding and selection trials, shifting the paradigm from identifying the maximum tolerated dose (MTD) to determining the optimal biological dose (OBD), which optimizes the risk and benefit of treatments. The FDA’s guidance emphasizes the importance of collecting sufficient toxicity and efficacy data across multiple doses and considering late-onset cumulative toxicity that often results in tolerability issues. To address these challenges, we propose the BE-BOIN (Backfill time-to-Event Bayesian Optimal INterval) design, which allows backfilling patients into safe and effective doses during dose escalation and accommodates late-onset toxicities. BE-BOIN enables the collection of additional safety and efficacy data to enhance the accuracy and reliability of OBD selection and supports real-time dose decisions for new patients. Our simulation studies show that BE-BOIN accurately identifies the MTD and OBD while significantly reducing trial duration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Eli Lilly and Company, Indianapolis, IN, USA.
- Department of Biostatistics and Data Science, The University of Texas Health Science Center, Houston, TX, USA.
- Astellas Pharma Global Development Inc., Northbrook, IL, USA.
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA. yyuan@mdanderson.org.
Förderung
- NCI NIH HHS
- National Cancer Institute
Zitieren
APA
Chen, K., Zhao, Y., Takeda, K., & Yuan, Y. (2026). BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity. Therapeutic Innovation & Regulatory Science, 60(6), 1848-1860. https://doi.org/10.1007/s43441-026-00994-0
Vancouver
Chen K, Zhao Y, Takeda K, Yuan Y. BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity. Therapeutic Innovation & Regulatory Science. 2026;60(6):1848-1860. doi:10.1007/s43441-026-00994-0
BibTeX
@article{Chen2026,
author = {Chen, Kai and Zhao, Yixuan and Takeda, Kentaro and Yuan, Ying},
title = {BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity},
journal = {Therapeutic Innovation & Regulatory Science},
year = {2026},
volume = {60},
number = {6},
pages = {1848--1860},
doi = {10.1007/s43441-026-00994-0}
}
EUVIMED