EUVIMEDEUVIMED entdecken
Crossref

Design and analysis of a hexadic tank system: classical and advanced control algorithms

Sagnik Mitra, Ganti Suryanarayana Murthy

Systems Microbiology and Biomanufacturing · 2026-07 · 6 (4)

DOI: 10.1007/s43393-026-00516-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Systems Microbiology and Biomanufacturing, online erschienen am 24.06.2026. Verfasst von Sagnik Mitra und 1 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Indian Institute of Technology Indore.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hexadic tank system represents an extension of quadruple tank system for controlling non-growth-associated product dynamics in bioprocess industries, including two stage continuous fermentations, multiple distillation columns, pharmaceutical, and food processing applications. This study presents a comprehensive analysis encompassing theoretical foundations, simulation frameworks, hardware implementation, and experimental validation of three control algorithms: LQR, Linear MPC, and Robust MPC, evaluated under disturbance and non-disturbance conditions. Among the three control algorithms, Linear MPC with disturbances (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\hbox {LMPC}_{\text {D}}$$\end{document}) achieves superior performance with the lowest mean error (1.67), maximum error (2.00), control variance (3.47), and overall sensitivity (2.52), with high settling times. \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\hbox {RMPC}_{\text {D}}$$\end{document} shows the fastest minimum response (1.93 s) but exhibits higher mean error (2.5) and maximum error (5.0), and overall sensitivity (3.94). LQR controllers exhibit poor performance, with high sensitivity (94.08–226.47), large errors, and longer settling times (especially for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\hbox {LQR}_{\text {D}}$$\end{document}), rendering them unsuitable for practical implementation. All controllers maintain zero steady-state error with stable eigenvalues (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$-6.76\times 10^{-3}$$\end{document} to \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$-4.34\times 10^{-19}$$\end{document}). This confirms that the model predictive control strategies are optimal for tracking precision, disturbance rejection, and parameter insensitivity in bioprocess applications.

Förderung

  • Indian Institute of Technology Indore

Zitieren

APA

Mitra, S., & Murthy, G. S. (2026). Design and analysis of a hexadic tank system: classical and advanced control algorithms. Systems Microbiology and Biomanufacturing, 6(4). https://doi.org/10.1007/s43393-026-00516-x

Vancouver

Mitra S, Murthy GS. Design and analysis of a hexadic tank system: classical and advanced control algorithms. Systems Microbiology and Biomanufacturing. 2026;6(4). doi:10.1007/s43393-026-00516-x

BibTeX
@article{Mitra2026,
  author = {Mitra, Sagnik and Murthy, Ganti Suryanarayana},
  title = {Design and analysis of a hexadic tank system: classical and advanced control algorithms},
  journal = {Systems Microbiology and Biomanufacturing},
  year = {2026},
  volume = {6},
  number = {4},
  doi = {10.1007/s43393-026-00516-x}
}
Kostenlos starten →