Opportunistic bone mineral density assessment in pediatric scoliosis: validating Hounsfield unit measurement from lumbar CT images
Spine Deformity · 20.07.2026
DOI: 10.1007/s43390-026-01509-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spine Deformity, online erschienen am 20.07.2026. Verfasst von Kosei Nagata und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, The University of Tokyo Hospital, Tokyo, Japan. knagata-tky@umin.ac.jp. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japanese Society for Bone and Mineral Research, Saitama Medical University.
Abstract (Originalsprache)
Background
Hounsfield Units (HU) derived from CT scans are a promising bone mineral density surrogate in pediatrics, yet their reliability in patients with scoliosis and significant lumbar tilt remains unknown. We investigated the reliability of HU measurements in adolescent idiopathic scoliosis (AIS), particularly addressing the impact of spinal tilt.
Methods
We retrospectively reviewed lumbar CT images of 11- to 19-year-old AIS patients who underwent posterior spinal fusion (July 2007–March 2024). HU values and lumbar tilt were measured at L1, L3, and L5. Reliability was assessed using intra-rater ( N = 36), inter-rater ( N = 30), and equivalence datasets ( N = 62) comparing standard pelvis-parallel images versus images reconstructed parallel to the vertebral body.
Results
Both intra-rater (ICC(1,1) > 0.95) and inter-rater (ICC(2,1) > 0.80) reliability were excellent. Measurements from standard pelvis-parallel images and reconstructed images showed stable overall equivalence (ICC(3,1) = 0.96). However, the percentage of cases with an HU value difference of 20 or more was 11.3% when the lumbar tilt angle was 10 degrees or greater, compared to 5.6% when the tilt angle was below 9 degrees.
Conclusion
Our analyses for AIS patients showed that vertebral HU measurements are reliable when using vertebral-parallel reconstructed images but standard pelvis-parallel images lose reliability with significant tilt. While our findings do not promote routine CT usage, our validated methodology provides a baseline technique that could potentially be applied to complex, high-risk cases where osteoporosis is prevalent and critical for surgical planning.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, The University of Tokyo Hospital, Tokyo, Japan. knagata-tky@umin.ac.jp.
- Department of Orthopedic Surgery, Saitama Medical University Saitama Medical Center, 1981 Kamoda, Kawagoe City, Saitama, 350-0844, Japan. knagata-tky@umin.ac.jp.
- Department of Orthopaedic Surgery, The University of Tokyo Hospital, Tokyo, Japan.
- Department of Orthopedic Surgery, Saitama Medical University Saitama Medical Center, 1981 Kamoda, Kawagoe City, Saitama, 350-0844, Japan.
Förderung
- Japanese Society for Bone and Mineral Research
- Saitama Medical University
Zitieren
APA
Nagata, K., Nakajima, K., Nakarai, H., Urayama, D., Yoshida, A., Komatsu, N., Nakamoto, H., Kato, S., Oshima, Y., Tanaka, S., Inui, H., Saita, K., & Taniguchi, Y. (2026). Opportunistic bone mineral density assessment in pediatric scoliosis: validating Hounsfield unit measurement from lumbar CT images. Spine Deformity. https://doi.org/10.1007/s43390-026-01509-5
Vancouver
Nagata K, Nakajima K, Nakarai H, Urayama D, Yoshida A, Komatsu N, et al. Opportunistic bone mineral density assessment in pediatric scoliosis: validating Hounsfield unit measurement from lumbar CT images. Spine Deformity. 2026. doi:10.1007/s43390-026-01509-5
BibTeX
@article{Nagata2026,
author = {Nagata, Kosei and Nakajima, Koji and Nakarai, Hiroyuki and Urayama, Daiki and Yoshida, Atsushi and Komatsu, Naoto and Nakamoto, Hideki and Kato, So and Oshima, Yasushi and Tanaka, Sakae and Inui, Hiroshi and Saita, Kazuo and Taniguchi, Yuki},
title = {Opportunistic bone mineral density assessment in pediatric scoliosis: validating Hounsfield unit measurement from lumbar CT images},
journal = {Spine Deformity},
year = {2026},
doi = {10.1007/s43390-026-01509-5}
}
EUVIMED