Physiologic and anesthetic predictors of false-positive motor-evoked potential alerts during pediatric spine surgery
Spine Deformity · 2026
DOI: 10.1007/s43390-026-01401-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spine Deformity, 2026. Verfasst von Alex La Poche und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA. alex.lapoche@downstate.edu. Hauptthemen laut MEDLINE: Evoked Potentials, Motor, Anesthesia, Intravenous, Monitoring, Intraoperative, Spine. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
False-positive transcranial motor-evoked potential (tcMEP) alerts during pediatric spinal deformity surgery can delay or alter surgical management. This cohort study evaluated anesthetic and physiologic predictors of false-positive alerts under standardized total intravenous anesthesia (TIVA).
Methods
All pediatric spine deformity surgeries with intraoperative tcMEP alerts (June–November 2024) at a single tertiary center were identified from a quality registry. Alerts were classified as false positive (FP), true positive (TP), or true negative (TN) by intraoperative assessment and postoperative outcomes. Standardized total intravenous anesthesia with bispectral index (BIS) and electroencephalography (EEG) monitoring was used. Physiologic and anesthetic variables were retrospectively extracted and compared using appropriate parametric and nonparametric tests ( p < 0.05).
Results
Of 99 patients during the study period, 15 experienced tcMEP alerts, yielding 631 timepoints: 80 FP, 13 TP, and 538 TN. BIS values were significantly lower during FP alerts (28.8 ± 14.5) than TP (53.6 ± 9.9) or TN (40.1 ± 12.9) ( p < 0.001). EEG suppression occurred in 36.4% of FP timepoints but in 0% of TP and 0.9% of TN events ( p < 0.001). Receiver operating characteristic (ROC) analysis showed that BIS had outstanding discrimination between false-positive and true-positive alerts (AUC 0.924, 95% CI: 0.823–1.00).
Conclusion
Periods of BIS suppression, in the setting of stable hemodynamics and anesthetic delivery, strongly correlate with false-positive tcMEP alerts. Incorporating BIS into intraoperative decision-making may help distinguish false positives from true neurologic injury, reducing unnecessary interruptions in pediatric spinal deformity surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA. alex.lapoche@downstate.edu.
- Department of Orthopedic Surgery, SUNY Downstate College of Medicine, Brooklyn, NY, USA. alex.lapoche@downstate.edu.
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.
- Department of Neurodiagnostics, Vanderbilt University Medical Center, Nashville, TN, USA.
- Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, TN, USA.
Zitieren
APA
La Poche, A., Montgomery, A., Sestito, J., Hutchinson, J., Romanelli, T., Franklin, A., Martus, J., Mencio, G., & Louer, C. (2026). Physiologic and anesthetic predictors of false-positive motor-evoked potential alerts during pediatric spine surgery. Spine Deformity. https://doi.org/10.1007/s43390-026-01401-2
Vancouver
La Poche A, Montgomery A, Sestito J, Hutchinson J, Romanelli T, Franklin A, et al. Physiologic and anesthetic predictors of false-positive motor-evoked potential alerts during pediatric spine surgery. Spine Deformity. 2026. doi:10.1007/s43390-026-01401-2
BibTeX
@article{LaPoche2026,
author = {La Poche, Alex and Montgomery, Austin and Sestito, John and Hutchinson, James and Romanelli, Thomas and Franklin, Andrew and Martus, Jeffrey and Mencio, Gregory and Louer, Craig},
title = {Physiologic and anesthetic predictors of false-positive motor-evoked potential alerts during pediatric spine surgery},
journal = {Spine Deformity},
year = {2026},
doi = {10.1007/s43390-026-01401-2}
}
EUVIMED