Instrumentation using robotics coupled with navigation in pediatric spine deformity surgery: a technical report of sacropelvic instrumentation
Spine Deformity · 2025
DOI: 10.1007/s43390-025-01047-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spine Deformity, 2025. Verfasst von Craig Birch und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA. Craig.Birch@childrens.harvard.edu. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Sacrum, Spinal Fusion, Scoliosis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This technical report presents the intraoperative experience of using robotic-assisted navigation (RAN) for sacropelvic instrumentation in pediatric spine deformity surgery. METHODS: A retrospective review of patients who underwent surgery using RAN for sacropelvic instrumentation at a single institution from 2019 to 2022 was conducted. In cases with screw confirmation imaging, screws were evaluated using the Gertzbein and Robbins classification scale. RESULTS: 52 cases were included. Average age at surgery was 14.1 years and 67.3% of patients were female. The most common diagnosis was spondylolisthesis (48.1%). The average major curve in scoliosis cases was 77°. A Schanz pin in the posterior superior iliac spine was placed in 98.1% of surgeries compared to 1 case with a spinous process clamp. Intraoperative 3D imaging scans (Scan & Plan) were used for 69.2% of the robotic registrations to the patient and intraoperative fluoroscopy-CT scans were used for 30.8%. 644 total screws were placed, with 427 placed robotically. Specifically, in the sacral-pelvic region, 98 S1, 18 S2, 58 S2AI, and 5 iliac screws were placed using RAN (179 screws). In 17 cases with 139 total robotic screws, post-instrumentation intraoperative 3D imaging or postoperative CT scans were obtained. Of these screws, 99.3% (138/139; 95% CI = 95.5-99.96) were placed accurately (Grade A or Grade B). One S2AI screw had an anterior breach on intraoperative 3D imaging scan and was changed prior to closure. Loss of RAN registration was observed in 2 cases (3.8%). No cases required return to the operating room for screw malposition. CONCLUSION: This study highlights high screw accuracy with no neurologic compromise associated with the use of RAN technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA. Craig.Birch@childrens.harvard.edu.
- Harvard Medical School, Boston, MA, USA. Craig.Birch@childrens.harvard.edu.
- Department of Orthopedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
- Harvard Medical School, Boston, MA, USA.
Zitieren
APA
Birch, C., Welch, N., Cook, D., & Hedequist, D. (2025). Instrumentation using robotics coupled with navigation in pediatric spine deformity surgery: a technical report of sacropelvic instrumentation. Spine Deformity. https://doi.org/10.1007/s43390-025-01047-6
Vancouver
Birch C, Welch N, Cook D, Hedequist D. Instrumentation using robotics coupled with navigation in pediatric spine deformity surgery: a technical report of sacropelvic instrumentation. Spine Deformity. 2025. doi:10.1007/s43390-025-01047-6
BibTeX
@article{Birch2025,
author = {Birch, Craig and Welch, Nicole and Cook, Danielle and Hedequist, Daniel},
title = {Instrumentation using robotics coupled with navigation in pediatric spine deformity surgery: a technical report of sacropelvic instrumentation},
journal = {Spine Deformity},
year = {2025},
doi = {10.1007/s43390-025-01047-6}
}
EUVIMED