Behavior of flow rate and rotational speed in blood components separation: an engineering approach to apheresis procedure

Shafie Rahmati, Amir Ali Hamidieh, Maryam Behfar, Leila Jafari, Alireza Mahdavian

Research on Biomedical Engineering · 2026-06 · 42 (2)

DOI: 10.1007/s42600-025-00449-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research on Biomedical Engineering, online erschienen am 12.05.2026. Verfasst von Shafie Rahmati und 4 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Performance of centrifugal blood component separators in apheresis is highly dependent on operational parameters such as rotational speed and inlet flow rate. However, fixed-protocol systems limit multi-objective optimization and adaptability to donor variability.

Objective

To investigate the coupled effects of rotational speed and flow rate on separation performance and to identify optimal operating conditions using a programmable centrifugal separator.

Methods

A programmable separator was evaluated across rotational speeds of 500–9000 RPM and flow rates of 1–200 mL/min. Experiments were conducted with five replicates per condition (n = 5). Key performance metrics included separation efficiency, plasma purity, platelet collection rate, and temporal efficiency. Data were analyzed using ANOVA and response surface methodology for multi-objective optimization.

Results

Maximum separation efficiency (93% ± 2%) was achieved at 7000 RPM and 100 mL/min. Optimal plasma purity occurred at 6000 RPM and 100 mL/min, while peak platelet collection rate was observed at 4000 RPM and 75 mL/min. Multi-objective optimization identified 6500 RPM and 85 mL/min as optimal, yielding 90.6% efficiency, high purity (minimal RBC contamination), platelet collection rate of 3.5 × 10³/μL·min, and temporal efficiency of 99 mL/min. Cell viability remained within 96–99%.

Conclusion

Programmable control of rotational speed and flow rate enables significant improvements in separation performance. The proposed system supports adaptive, multi-objective optimization and has strong potential for personalized apheresis and enhanced bioprocess efficiency.

Zitieren

APA

Rahmati, S., Hamidieh, A. A., Behfar, M., Jafari, L., & Mahdavian, A. (2026). Behavior of flow rate and rotational speed in blood components separation: an engineering approach to apheresis procedure. Research on Biomedical Engineering, 42(2). https://doi.org/10.1007/s42600-025-00449-9

Vancouver

Rahmati S, Hamidieh AA, Behfar M, Jafari L, Mahdavian A. Behavior of flow rate and rotational speed in blood components separation: an engineering approach to apheresis procedure. Research on Biomedical Engineering. 2026;42(2). doi:10.1007/s42600-025-00449-9

BibTeX
@article{Rahmati2026,
  author = {Rahmati, Shafie and Hamidieh, Amir Ali and Behfar, Maryam and Jafari, Leila and Mahdavian, Alireza},
  title = {Behavior of flow rate and rotational speed in blood components separation: an engineering approach to apheresis procedure},
  journal = {Research on Biomedical Engineering},
  year = {2026},
  volume = {42},
  number = {2},
  doi = {10.1007/s42600-025-00449-9}
}
Kostenlos starten →